SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-428612"
 

Sökning: id:"swepub:oai:DiVA.org:uu-428612" > Optimal Designs for...

Optimal Designs for Model-Based Assessment of Insulin Sensitivity and Glucose Effectiveness.

Ibrahim, Moustafa M. A. (författare)
Uppsala universitet,Institutionen för farmaci,Institutionen för farmaceutisk biovetenskap
Redestad, Erik (författare)
Kjellsson, Maria C., docent, 1975- (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap
 (creator_code:org_t)
2020-07-29
2021
Engelska.
Ingår i: Journal of clinical pharmacology. - : John Wiley & Sons. - 0091-2700 .- 1552-4604. ; 61:1, s. 116-124
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The integrated minimal model allows assessment of clinical diagnosis indices, for example, insulin sensitivity (SI ) and glucose effectiveness (SG ), from data of the insulin-modified intravenous glucose tolerance test (IVGTT), which is laborious with an intense sampling schedule, up to 32 samples. The aim of this study was to propose a more informative, although less laborious, IVGTT design to be used for model-based assessment of SI and SG . The IVGTT design was optimized simultaneously for all design variables: glucose and insulin infusion doses, time of glucose dose and start of insulin infusion, insulin infusion duration, sampling times, and number of samples. Design efficiency was used to compare among different designs. The simultaneously optimized designs showed a profound higher efficiency than both standard rich (32 samples) and sparse (10 samples) designs. The optimized designs, after removing replicate sample times, were 1.9 and 7.1 times more efficient than the standard rich and sparse designs, respectively. After including practical aspects of the designs, for example, sufficient duration between samples and avoidance of prolonged hypoglycemia, we propose 2 practical designs with fewer sampling times and lower input of glucose and insulin than standard designs, constrained to prevent hypoglycemia. The optimized practical rich design is equally efficient in assessing SI and SG as the rich standard design, but with half the number of the samples, while the optimized practical sparse design has 1 less sample and requires 4.6 times fewer individuals for equal certainty when assessing SI and SG than the sparse standard design.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Farmaceutiska vetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Pharmaceutical Sciences (hsv//eng)

Nyckelord

glucose effectiveness
insulin sensitivity
minimal model
nonlinear mixed effects
optimal design

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ibrahim, Moustaf ...
Redestad, Erik
Kjellsson, Maria ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Farmaceutiska ve ...
Artiklar i publikationen
Journal of clini ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy