Evaluation of Regularized Image Reconstruction for Clinical Positron Emission Tomography

Lindström, Elin (författare)
Uppsala universitet,Radiologi
Lubberink, Mark, Professor (preses)
Uppsala universitet,Radiologi
Sörensen, Jens, Associate Professor (preses)
Uppsala universitet,Radiologi
visa fler...
Sundin, Anders, Professor, 1954- (preses)
Uppsala universitet,Radiologi
Larsson Strömvall, Anne, Associate Professor (opponent)
Department of Radiation Sciences, Umeå University
visa färre...
 (creator_code:org_t)
ISBN 9789151314259
Uppsala : Acta Universitatis Upsaliensis, 2022
Engelska 64 s.
Serie: Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, 1651-6206 ; 1812
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Positron emission tomography (PET) combined with computed tomography (CT) is a widely used noninvasive molecular imaging modality with a broad range of clinical applications in oncology, neurology, and cardiology. Producing imperative image quality and accurate quantification are important driving forces behind the technological advances within PET image reconstruction and system development. To ensure clinical quality and to understand how the modern state-of-the-art PET/CT systems and image reconstruction methods compare with older systems and reconstruction methods they need to be evaluated and assessed in a clinical setting. This thesis summarizes six studies assessing the effect of state-of-the-art image reconstruction methods and the introduction of digital PET on image quality and quantitative outcomes of clinical PET scans in oncology, neurology, and cardiology. The overall aim was to evaluate, optimize, and compare quantitative results of regularized image reconstruction with the current standard reconstruction method used in routine clinical practice, ordered subsets expectation maximization (OSEM).The optimal setting of regularized image reconstruction by block-sequential regularized expectation maximization (BSREM) was found to be tracer dependent, and a potential clinical benefit in terms of image quality measures of BSREM over OSEM was found when applied for whole-body 18F-FDG, 68Ga-DOTATOC, 18F-fluorde, 11C-acetate, and 68Ga-PSMA-11 PET imaging. Software-aided assessment of neurodegenerative disease evaluated with 18F-FDG and 18F-flutemetamol was affected by image reconstruction methods and should be used with caution when employing other image reconstruction methods than those used for acquisition of the normal database. In contrast, changes in reconstruction settings were shown to not implicate myocardial blood flow (MBF) based on 15O-water PET analyzed using automated software. This shows that diagnostic MBF cutoff values can be consistently used for 15O-water. Also, large variations in image noise with three different image reconstruction methods did not impact quantitative cerebral blood flow (CBF) in white and gray matter volumes of interest with 15O-water brain PET to any large extent.BSREM image reconstruction shows a great potential clinical benefit providing improved image quality measures with a subsequent possibility of shortening image acquisition durations and/or lowering amount of radioactivity needed for each examination.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Positron emission tomography
PET/CT
molecular imaging
image reconstruction
regularized reconstruction
quantification
oncology
neurology
cardiology
Medicinsk radiofysik
Medical Radiophysics

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy