SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-474857"
 

Sökning: id:"swepub:oai:DiVA.org:uu-474857" > Optimal Design of t...

Optimal Design of the Annular Groove Phase Mask Central Region

König, Lorenzo (författare)
Université de Liège, Belgium
Absil, Olivier (författare)
Université de Liège, Belgium
Lobet, Michaël (författare)
University of Namur, Belgium
visa fler...
Delaicroix, Christian (författare)
Université de Liège, Belgium
Karlsson, Mikael (författare)
Uppsala universitet,Tillämpad materialvetenskap
Orban de Xivry, Gilles (författare)
Université de Liège, Belgium
Loicq, Jérôme (författare)
Centre Spatial de Liège, Belgium/Delft University of Technology, Netherlands
visa färre...
 (creator_code:org_t)
2022
2022
Engelska.
Ingår i: Optics Express. - 1094-4087. ; 30:15, s. 27048-27063
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Vortex phase masks have been shown to be an efficient means to reduce the blinding stellar light in high-contrast imaging instruments. Once placed at the focal plane of the telescope, the helical phase ramp of a vortex phase mask diffracts the light of a bright on-axis source outside the re-imaged telescope pupil, while transmitting the light of a faint off-axis companion nearly unaffected. The Annular Groove Phase Mask (AGPM) is a broadband metasurface implementation of a vector vortex phase mask using the artificial birefringence of a circular subwavelength grating etched onto a diamond substrate. To date, the AGPM design has been optimized using rigorous coupled-wave analysis (RCWA), which is a valid tool to simulate periodic straight gratings. However, we have now reached a performance level where the curvature of the grating lines at the center becomes a limiting factor. Here, we use a finite-difference time-domain (FDTD) method to correctly describe the AGPM performance, including the effect of the curved grating close to its center. We confirm the validity of this simulation framework by comparing its predictions with experimental results obtained on our infrared coronagraphic test bench, and we show that RCWA fails at reproducing correctly the central AGPM performance, confirming the need for a full 3d simulation tool such as FDTD. Finally, we use FDTD to optimize the grating parameters at the AGPM center, and conclude with a new optimal design.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy