SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-4761"
 

Sökning: id:"swepub:oai:DiVA.org:uu-4761" > Method Development ...

Method Development in Quantitative and Structural Proteomics using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Hagman, Charlotte, 1973- (författare)
Uppsala universitet,Institutionen för teknikvetenskaper
Håkansson, Per (preses)
Bergquist, Jonas (preses)
visa fler...
Buijs, Jos (preses)
Przybylski, Michael, Professor (opponent)
Department of Chemistry, Konstanz
visa färre...
 (creator_code:org_t)
ISBN 9155461344
Uppsala : Acta Universitatis Upsaliensis, 2005
Engelska 52 s.
Serie: Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, 1651-6214 ; 6
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • In this thesis, methods for studying different aspects of proteomics were developed with Fourier Transform Ion Cyclotron Resonance, (FTICR), mass spectrometry. The FTICR technique provides ultra-high mass resolving power, mass accuracy at sub ppm level and sensitivity in the attomole region.Methods for quantifying biomarkers in body fluids such as cerebrospinal fluid, (CSF), and plasma were developed. Two sets of global markers with different properties were used for quantitative analysis; S-Methyl Thioacetimidate, (SMTA), and S-Methyl Thiopropionimidate, (SMTP), and [H4]- and [D4]-1-Nicotinoyloxy succinimide ester. Reduced ion suppression and higher sensitivity was obtained by coupling a High Performance Liquid Chromatography, (HPLC), system to the FTICR mass spectrometer.In body fluids, proteins and peptides are present in a broad dynamic concentration range. Therefore, depleting abundant proteins prior to analysis results in decreased ion suppression and increased sensitivity. Two commercial depletion kits were evaluated with the SMTA- and SMTP-markers.For both types of global markers, the experimental error for quantitative analysis of abundant proteins was less than 30%. This provides a lower limit for the protein up- and down regulations in complex solutions that can be monitored with HPLC-FTICR mass spectrometry.Together with the identity and quantity of selected proteins the structure, dynamics and interactions with other molecules are of great importance. The later can be elucidated with Hydrogen/Deuterium Exchange, (HDX), mass spectrometry. Structural information at high resolution can be obtained with Collision-Induced Dissociation, (CID), HDX mass spectrometry. In this thesis, exchange rates of amide hydrogens in peptides were in excellent agreement with NMR results.In some cases, the CID-fragments have different gas-phase exchange properties and as a consequence the solution phase exchange process can not be monitored. By applying Electron Capture Dissociation, (ECD), at ultra-high vacuum, the exchange process at a specific residue could be monitored.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Nyckelord

Biotechnology
Cerebrospinal Fluid
Electrospray Ionization
Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Global Markers
High Performance Liquid Chromatography
Gas-Phase Exchange
Hydrogen/Deuterium Exchange
Plasma
Protoemics
Quantification
Structural Elucidation
Bioteknik
Bioengineering
Bioteknik

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy