SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-487646"
 

Sökning: id:"swepub:oai:DiVA.org:uu-487646" > Chicken antibodies ...

Chicken antibodies are highly suitable for particle enhanced turbidimetric assays

Larsson, Anders (författare)
Uppsala universitet,Klinisk kemi
Campbell, Andrew (författare)
NABAS AS, Ås, Norway.
Eriksson, Mats B (författare)
Uppsala universitet,Anestesiologi och intensivvård,NOVA Medical School, New University of Lisbon, Lisboa, Portugal
 (creator_code:org_t)
2022-10-11
2022
Engelska.
Ingår i: Frontiers in Immunology. - : Frontiers Media S.A.. - 1664-3224. ; 13
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Antibody-based assays are commonly used in clinical laboratories for analyzing plasma, serum and other samples for particular protein markers. Although such assays have been traditionally based on antibodies raised in mammals (e.g., mice, rabbits, goats), there are several advantages of using avian antibodies (IgY) raised in chickens, including production volumes, costs, and ethical/animal welfare considerations. A further disadvantage of using mammalian IgG in such assays is the potential for agglutination when exposed to rheumatoid factor (RF) in serum. However, when used in the free form the immune complexes formed with avian antibodies have been reported to have less ability than those formed with mammalian antibodies to cause the light scatter which are used for instrument measurement. In addition, when the amount of antigen exceeds the maximum precipitating point in relation to the amount of antibody, there is a rapid decline in the absorbance values of the immune complexes (antigen excess) when IgY is used. However, when avian antibodies are conjugated to a substrate and used in particle enhanced turbidimetric assays (PETIA), these problems are avoided. Here we investigated three clinical assays using chicken antibodies, one using free (unbound) IgY and two with IgY-based PETIA. The IgY PETIA demonstrated a strong scatter response, even at high antigen concentrations in contrast to the steep decline seen with free IgY antibodies. IgY PETIA reagents can provide test results with low coefficient of variation (<1% for duplicate samples). We also investigated the effect of RF on agglutination of mammalian antibodies (IgG from mouse, rabbit, sheep, and human) and chicken antibodies. Whereas agglutination was observed with all the mammalian antibodies in the presence of RF, this was not observed at all with chicken IgY. Our results support the growing body of evidence that chicken egg yolks can thus be a valuable source of antibodies for use in PETIA in clinical laboratories.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Nyckelord

PETIA
chicken IgY
cystatin C
free light chains
immunoassays
particle enhanced turbidimetric assay

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Larsson, Anders
Campbell, Andrew
Eriksson, Mats B
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
Artiklar i publikationen
Frontiers in Imm ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy