A novel SAR reduction technique for implantable antenna using conformal absorber metasurface

Das, Soumyadeep (författare)
Indian Inst Engn Sci & Technol, Dept Elect & Telecommun, Howrah, India.
Mitra, Debasis (författare)
Indian Inst Engn Sci & Technol, Dept Elect & Telecommun, Howrah, India.
Chezhian, Arvind S. (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa fler...
Mandal, Bappaditya (författare)
Uppsala universitet,Fasta tillståndets elektronik
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa färre...
Indian Inst Engn Sci & Technol, Dept Elect & Telecommun, Howrah, India Fasta tillståndets elektronik (creator_code:org_t)
2022-08-23
2022
Engelska.
Ingår i: Frontiers in Medical Technology. - : Frontiers Media S.A.. - 2673-3129. ; 4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, a conformal absorber metasurface has been designed and used for reducing the specific absorption rate (SAR) of an implantable antenna. SAR reduction of implantable antennas is one of the significant design aspects to be considered for their use in modern-day healthcare applications. The introduction of the absorber metasurface restricts the back radiation of the antenna to control the SAR value. This technique decreases the maximum SAR value by 24% and also reduces the average SAR distribution significantly without affecting the desired antenna gain. A reduction in SAR value indicates the decrease in radiation absorption by human tissue, and thus, decreases the possibility of health hazards due to EM radiation. Later, this antenna-absorber system is designed as a capsule module for increased mobility and less-invasiveness. The redundancy of invasive surgery increases acceptance of the capsule module designs of implantable antennas and devices for various biomedical usages. In vitro testing of the fabricated prototype has been carried out inside a multi-layer porcine slab to verify the effectiveness of this unique SAR reduction technique.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

absorber metasurface
biomedical application
capsule antenna module
conformal metasurface
SAR reduction

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy