SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-508558"
 

Sökning: id:"swepub:oai:DiVA.org:uu-508558" > Development of boro...

Development of boron doped diamond electrodes material for heavy metal ion sensor with high sensitivity and durability

Kim, Shin (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
Jeong, Yesul (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
Park, Min-Ouk (författare)
Suntech Engn Co Ltd, Technol Res Inst, Daegu, South Korea.
visa fler...
Jang, Yujin (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
Bae, Jong-Seong (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
Hong, Kyong-Soo (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
Kim, Seohan (författare)
Uppsala universitet,Fasta tillståndets fysik,Pusan Natl Univ, Mat Technol Res Inst, Busan, South Korea.
Song, Pungkeun (författare)
Pusan Natl Univ, Dept Mat Sci & Engn, Busan, South Korea.
Yoon, Jang-Hee (författare)
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea.
visa färre...
Korea Basic Sci Inst KBSI, Busan Ctr, Busan, South Korea Suntech Engn Co Ltd, Technol Res Inst, Daegu, South Korea. (creator_code:org_t)
Elsevier BV, 2023
2023
Engelska.
Ingår i: JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY. - : Elsevier BV. - 2238-7854 .- 2214-0697. ; 23, s. 1375-1385
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We report on the optimized substrate pretreatment and deposition process conditions for boron-doped diamond (BDD) electrodes fabricated by hot-filament chemical vapor deposition (HFCVD). The optimized BDD electrode with a doping concentration of 8000 ppm showed high accuracy and precision in detecting Cd(II), Pb(II), and Cu(II) ions. In addition, this demonstrates excellent selectivity against external metal ions under the optimized stripping voltammetry measurement conditions. The detection limits of the target ions of Cd(II), Pb(II), and Cu(II) were 0.55 (+/- 0.05), 0.43 (+/- 0.04), and 0.74 (+/- 0.06) mg/L (S/N = 3), respectively. In real samples spiked with 100 mg/L Cd(II), Pb(II), and Cu(II), both the accuracy and precision of the BDD electrode were within 5%; the interference with organic matter was also negligible. The excellent selectivity and long-term stability indicate that the BDD electrode developed in this study are potentially useful for online water environment monitoring systems.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Kemi -- Materialkemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Materials Chemistry (hsv//eng)

Nyckelord

Boron doped diamond
Environmental chemistry
Electrodes of anodic stripping
voltammetry
Heavy metal detection sensors
Water quality monitoring

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy