SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-511255"
 

Sökning: id:"swepub:oai:DiVA.org:uu-511255" > Resilience to extre...

Resilience to extreme storm conditions : A comparative study of two power systems with varying dependencies on offshore wind

Forsberg, Samuel (författare)
Uppsala universitet,Elektricitetslära,Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden
Göteman, Malin, 1980- (författare)
Uppsala universitet,Elektricitetslära,Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden
Thomas, Karin (författare)
Uppsala universitet,Elektricitetslära
visa fler...
Bergkvist, Mikael (författare)
Uppsala universitet,Elektricitetslära,Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden
visa färre...
 (creator_code:org_t)
Elsevier, 2024
2024
Engelska.
Ingår i: Results in Engineering (RINENG). - : Elsevier. - 2590-1230. ; 23
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the next decades, the dependencies on power production from renewable energy sources are expected to increase dramatically. A transition towards large-scale offshore wind farms together with an increased electrification of the industry and transportation sectors introduces new vulnerabilities to society. Further, extreme weather events are expected to increase in intensity and frequency, driven by climate change. However, there are significant knowledge gaps concerning the impacts of severe weather conditions on the resilience of power systems with large dependencies on offshore wind. In the present study, a comparison between two different power systems’ resilience to historical extreme storm conditions has been conducted. The power systems are the IEEE39-bus New England model and the Great Britain model. The results show significant differences between the two power systems, which underlying reasons are analysed and explained. With an offshore wind penetration level of 30 %, the New England model stays intact in terms of connected load. When increasing the penetration level to 40 %, about 10 % of the total connected load gets disconnected, whereas about 33 % of the load gets disconnected with a penetration level of 50 %. The Great Britain model stays intact in terms of connected load with a penetration level of at least 49 %.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Nyckelord

Extreme weather event
Offshore wind
Power system
Resilience
Electrical Engineering with specialization in Systems Analysis
Elektroteknik med inriktning mot systemanalys

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy