Sökning: id:"swepub:oai:DiVA.org:uu-511728" >
Bilateral Implantat...
Bilateral Implantation of Double-Branched Iliac Branch Devices for Endovascular Repair of Aorto-Bi-Iliac Aneurysm With Concomitant Hypogastric Aneurysms : The Quadruple Branch
-
- Friesen, Lia (författare)
- Univ Hosp Muenster, Dept Vasc & Endovasc Surg, Albert Schweitzer Campus 1, D-48149 Munster, Germany.
-
- Asciutto, Giuseppe (författare)
- Uppsala universitet,Kärlkirurgi
-
- Schaefers, Johannes Frederik (författare)
- Univ Hosp Muenster, Dept Vasc & Endovasc Surg, Albert Schweitzer Campus 1, D-48149 Munster, Germany.
-
visa fler...
-
- Oberhuber, Alexander (författare)
- Univ Hosp Muenster, Dept Vasc & Endovasc Surg, Albert Schweitzer Campus 1, D-48149 Munster, Germany.
-
visa färre...
-
Univ Hosp Muenster, Dept Vasc & Endovasc Surg, Albert Schweitzer Campus 1, D-48149 Munster, Germany Kärlkirurgi (creator_code:org_t)
- 2022-05-03
- 2023
- Engelska.
-
Ingår i: Journal of Endovascular Therapy. - : Sage Publications. - 1526-6028 .- 1545-1550. ; 30:4, s. 520-524
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: The purpose of this report is to describe the use of a double-branched custom-made iliac branch device (IBD) for the endovascular repair of an aorto-bi-iliac aneurysm with concomitant bilateral hypogastric aneurysms. Technique: A 61-year-old man on peritoneal dialysis underwent a computed tomography (CT) of the infrarenal aorta before planned kidney transplantation. The CT showed an asymptomatic aorto-bi-iliac aneurysm of 54 mm involving the hypogastric artery (HA) bilaterally (right HA 31 mm; left HA 40 mm). The treatment consisted of an endovascular aortic repair (EVAR) and the bilateral implantation of custom-manufactured IBDs with double inner branches to preserve both superior and inferior gluteal arteries. At 1 year follow-up, the patient remains free of symptoms and the postoperative CT showed a successfully excluded aneurysm with patent bridging stent grafts to all HA branches. Conclusion: The bilateral implantation of double-branched IBDs is a feasible technique. Preservation of both hypogastric arteries and its branches can be achieved with this technique and therefore decrease the risk of buttock claudication and other ischemic complications.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- aneurysm
- iliac branch device
- common iliac artery
- external iliac artery
- hypogastric artery
- stent
- endovascular aortic repair
- EVAR
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas