SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-513036"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-513036" > Spent Nuclear Fuel ...

Spent Nuclear Fuel passive gamma analysis and reproducibility : Application to SKB-50 assemblies

Solans, Virginie (författare)
Uppsala University,Uppsala universitet,Tillämpad kärnfysik
Sjöstrand, Henrik, 1978- (författare)
Uppsala University,Uppsala universitet,Tillämpad kärnfysik
Jansson, Peter (författare)
Uppsala University,Uppsala universitet,Tillämpad kärnfysik
visa fler...
Schillebeeckx, Peter (författare)
European Commission
Grape, Sophie, 1982- (författare)
Uppsala University,Uppsala universitet,Tillämpad kärnfysik
Branger, Erik, 1988- (författare)
Uppsala University,Uppsala universitet,Tillämpad kärnfysik
Sjöland, Anders (författare)
Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,The Swedish Nuclear Fuel and Waste Management Company
visa färre...
 (creator_code:org_t)
Elsevier, 2023
2023
Engelska.
Ingår i: Annals of Nuclear Energy. - : Elsevier. - 0306-4549 .- 1873-2100. ; 192
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This work studies the reproducibility of passive gamma spectroscopy measurements for spent nuclear fuels (SNFs). The fifty assemblies used for this study span over a variety of initial enrichments, burnups, and cooling times. These SNFs have been measured in two different gamma axial measurement campaigns. The net peak counts are determined for Cs-137, Eu-154 and Cs-134. Furthermore, a sensitivity analysis of the relative position of the SNF and the detector is performed. Most importantly, this work describes a methodology using an intrinsic self-calibration procedure that can be used to compare the relative activities of the radionuclides without the need for detailed knowledge about the measurement set-up and its properties. The reproducibility of the Cs-137 net peak count rate ranges between 2% and 4%. Systematic reproducibility of the ratio of Eu-154 and Cs-134 to Cs-137 is between 0,4% - 5 % using the intrinsic self-calibration method.

Ämnesord

NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)
NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

SNF
SKB-50
Gamma measurements
Reproducibility
Gamma measurements
Reproducibility
SKB-50
SNF

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy