SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-55733"
 

Sökning: id:"swepub:oai:DiVA.org:uu-55733" > Attenuation of chan...

Attenuation of changes in leukocyte surface markers and complement activation with heparin-coated cardiopulmonary bypass

Moen, Oddvar (författare)
Högåsen, Kolbjörn (författare)
Fosse, Erik (författare)
visa fler...
Dregelid, Einar (författare)
Brockmeier, Vibeke (författare)
Venge, Per (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper
Harboe, Morten (författare)
Mollnes, Tom Eirik (författare)
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Annals of Thoracic Surgery. - 0003-4975 .- 1552-6259. ; 63:1, s. 105-111
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The inflammatory response induced by cardiopulmonary bypass can result in severe organ dysfunction in some patients. This postperfusion response is caused mainly by contact between blood and the foreign surface of the cardiopulmonary bypass equipment and includes adhesion of leukocytes to vascular endothelium, which precedes a series of events that mediate inflammatory damage to tissues. METHODS: Low-risk patients accepted for coronary artery bypass grafting were randomized to operation with the cardiopulmonary bypass surface either completely heparin coated (Duraflo II) or uncoated. There were 12 patients in each group. Blood plasma sampled during cardiopulmonary bypass was analyzed for complement activation (C3bc and terminal SC5b-9 complement complex) and neutrophil activation (lactoferrin and myeloperoxidase). In addition, neutrophils, monocytes, and platelets were counted, and the expression of surface markers on the neutrophils and monocytes (complement receptor [CR] 1, CR3, CR4, and L-selectin) and on the platelets (P-selectin and CD41) was quantified with flow cytometry. RESULTS: Clinical and surgical results were similar in both groups. In the group with the heparin-coated surface, the formation of the terminal SC5b-9 complement complex was significantly reduced, and the counts of circulating leukocytes and platelets were significantly less reduced initially but were higher at the end of cardiopulmonary bypass compared with baseline. Also, the expression of CR1, CR3, and CR4 was significantly less upregulated and the L-selectin, significantly less downregulated on monocytes and neutrophils. CONCLUSIONS: We conclude that heparin coating reduces complement activation and attenuates the leukocyte integrin and selectin response that occurs when uncoated circuits are used.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy