SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-67515"
 

Sökning: id:"swepub:oai:DiVA.org:uu-67515" > Simultaneous quanti...

Simultaneous quantification of the enantiomers of verapamil and its N-demethylated metabolite in human plasma using liquid chromatography-tandem mass spectrometry

Hedeland, Mikael (författare)
Fredriksson, Elisabeth (författare)
Lennernäs, Hans (författare)
Uppsala universitet,Institutionen för farmaci
visa fler...
Bondesson, Ulf (författare)
Uppsala universitet,Institutionen för läkemedelskemi,Analytisk Farmaceutisk Kemi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2004
2004
Engelska.
Ingår i: Journal of chromatography. B. - : Elsevier BV. - 1570-0232 .- 1873-376X. ; 804:2, s. 303-311
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A stereoselective bioanalytical method for the simultaneous quantification of the enantiomers of verapamil and its active main metabolite norverapamil in human plasma has been developed and validated. The samples were analysed by liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) in the Selected Reaction Monitoring (SRM) mode using a deuterated internal standard. The stationary phase used for the chiral separation was a Chiral-AGP. The enantiomers of verapamil were selectively detected from those of norverapamil by the mass spectrometer due to different molecular masses, although there was a chromatographic co-elution. Thus, time-consuming procedures like achiral preseparation or chemical derivatisation could be avoided. Higher detection sensitivity than earlier published methods based on fluorescence detection was obtained, although a mobile phase of high water-content and high flow-rate was introduced into the electrospray interface (85% aqueous ammonium acetate pH 7.4 +15% acetonitrile at 0.6 ml/min). The enantiomers of verapamil and norverapamil could be quantified at levels down to 50 pg and 60 pg/500 microl plasma sample, respectively, with R.S.D. in the range of 3.6-7.8%. The presented method was successfully applied to an in vivo intestinal absorption and bioavailability study in humans, using the Loc-I-Gut method.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy