A prospective comparison of duplex ultrasonography, Captopril renography, MRA and CTA in assessing renal artery stenosis

Eklöf, Hampus (författare)
Uppsala universitet,Enheten för radiologi,Nyman
Ahlström, Håkan (författare)
Uppsala universitet,Enheten för radiologi,Ahlstrom
Magnusson, Ann christin (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
visa fler...
Andersson, Lars-Göran (författare)
Uppsala universitet,Klinisk fysiologi
Andrén, Bertil (författare)
Uppsala universitet,Klinisk fysiologi
Hägg, Anders (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper
Bergqvist, David (författare)
Uppsala universitet,Kärlkirurgi
Nyman, Rickard (författare)
Uppsala universitet,Enheten för radiologi,Nyman
visa färre...
 (creator_code:org_t)
2016-08-30
2006
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 47:8, s. 764-774
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To prospectively compare the diagnostic accuracy of duplex ultrasonography, captopril renography, computed tomography angiography (CTA), and 3D Gd magnetic resonance angiography (MRA) in diagnosing hemodynamically significant renal artery stenosis (RAS). Material and Methods: The standard of reference was measurement of transstenotic pressure gradient. Fifty-eight hypertensive patients with suspicion of RAS were evaluated, when possible, by all five techniques. Sensitivity and specificity to detect RAS were compared for each technique on both a patient and kidney basis. Discrepancies were evaluated separately and classified as borderline, method dependent, or operator dependent. Results: The prevalence of RAS was 77%. The sensitivity/specificity of ultrasonography, captopril renography, CTA, and MRA in detecting kidneys with RAS was 73/71%, 52/63%, 94/62%, and 93/91%, respectively. Ultrasonography had a significantly lower sensitivity than CTA and MRA (P < 0.001) but higher than captopril renography (P = 0.013). Borderline RAS was the main cause for discrepancies. Conclusion: MRA and CTA were significantly better than duplex ultrasonography and captopril renography in detecting hemodynamically significant RAS. The ultrasonography criteria for RAS based on the evaluation of renal peak systolic velocity and renal/aortic ratio are questionable. Captopril renography cannot be recommended for assessing RAS.

Nyckelord

atherosclerosis
comparative studies
kidney
technology assessment
vascular
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy