Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD.

Lofthag-Hansen, Sara, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology,Public Dental Health, Göteborg
Thilander-Klang, Anne, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Göteborg, Sweden
Ekestubbe, Annika, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology,Department of Oral and Maxillofacial Radiology The Sahlgrenska Academy at Göteborg University, Sweden
visa fler...
Helmrot, Ebba (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen
Gröndahl, Kerstin, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology,Department of Oral and Maxillofacial Radiology, The Sahlgrenska Academy at Göteborg University, Sweden
visa färre...
 (creator_code:org_t)
British Institute of Radiology, 2008
2008
Engelska.
Ingår i: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X .- 1476-542X. ; 37:2, s. 72-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: This study evaluates two methods for calculating effective dose, CT dose index (CTDI) and dose-area product (DAP) for a cone beam CT (CBCT) device: 3D Accuitomo at field size 30x40 mm and 3D Accuitomo FPD at field sizes 40x40 mm and 60x60 mm. Furthermore, the effective dose of three commonly used examinations in dental radiology was determined. METHODS: CTDI(100) measurements were performed in a CT head dose phantom with a pencil ionization chamber connected to an electrometer. The rotation centre was placed in the centre of the phantom and also, to simulate a patient examination, in the upper left cuspid region. The DAP value was determined with a plane-parallel transmission ionization chamber connected to an electrometer. A conversion factor of 0.08 mSv per Gy cm(2) was used to determine the effective dose from DAP values. Based on data from 90 patient examinations, DAP and effective dose were determined. RESULTS: CTDI(100) measurements showed an asymmetric dose distribution in the phantom when simulating a patient examination. Hence a correct value of CTDI(w) could not be calculated. The DAP value increased with higher tube current and tube voltage values. The DAP value was also proportional to the field size. The effective dose was found to be 11-77 microSv for the specific examinations. CONCLUSIONS: DAP measurement was found to be the best method for determining effective dose for the Accuitomo. Determination of specific conversion factors in dental radiology must, however, be further developed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Cone-Beam Computed Tomography
instrumentation
Humans
Phantoms
Imaging
Radiation Dosage
Radiometry
Tomography Scanners
X-Ray Computed
radiation dosimetry; limited cone beam computed tomography
Radiological physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy