SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/108218"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/108218" > Radiation-induced r...

Radiation-induced rib fractures after hypofractionated stereotactic body radiation therapy of non-small cell lung cancer: a dose- and volume-response analysis.

Pettersson, Niclas, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Nyman, Jan, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences,Institute of Clinical Sciences, Department of Oncology
Johansson, Karl-Axel (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. - : Elsevier BV. - 1879-0887. ; 91:3, s. 360-8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND PURPOSE: The aim of this study is to analyse the dose-response and the volume-response of radiation-induced rib fractures after hypofractionated stereotactic body radiation therapy (SBRT). MATERIALS AND METHODS: During the period 1998-2005, 68 patients with medically inoperable stage I non-small cell lung cancer (NSCLC) were treated with hypofractionated SBRT to 45 Gy in 3 fractions. Among the 33 patients with complete treatment records and radiographic follow-up exceeding 15 months (median: 29 months), 13 fractures were found in seven patients. Identifying all ribs receiving at least 21 Gy, 81 ribs (13 with and 68 without fracture) in 26 patients were separately contoured and their dose-volume histograms (DVHs) were obtained. The DVHs were assessed with the mean dose and cut-off models. Maximum likelihood estimation was used to fit dose-response and volume-response curves to each model. RESULTS: It was possible to quantify the risk of radiation-induced rib fracture using response curves and information contained in the DVHs. Absolute volumes provided better fits than relative volumes and dose-response curves were more suitable than volume-response curves. For the dose given by the 2 cm(3) cut-off volume, D(2 cm(3)), the logistic dose-response curve for three fractions was parameterised by D(50)=49.8 Gy and gamma(50)=2.05. Consequently, for a median follow-up of 29 months, if D(2 cm(3))<3 x 7.0 Gy the risk is close to 0, and the 5% and 50% risks are given by D(2 cm(3))=3 x 9.1 Gy and 3 x 16.6 Gy, respectively. CONCLUSIONS: In this group of patients, the risk for radiation-induced rib fracture following hypofractionated SBRT was related to the dose to 2 cm(3) of the rib.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Aged
Aged
80 and over
Carcinoma
Non-Small-Cell Lung
surgery
Dose Fractionation
Dose-Response Relationship
Radiation
Female
Humans
Likelihood Functions
Lung Neoplasms
surgery
Male
Middle Aged
Radiation Injuries
etiology
radiography
Radiation Tolerance
Radiosurgery
adverse effects
methods
Radiotherapy Dosage
Rib Fractures
etiology
radiography
Tomography
X-Ray Computed

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy