SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/113908"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/113908" > Morphological studi...

Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit.

Palmquist, Anders, 1977 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Lindberg, Fredrik (författare)
Uppsala universitet,Tillämpad materialvetenskap
Emanuelsson, Lena, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa fler...
Brånemark, Rickard, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Engqvist, Håkan (författare)
Uppsala universitet,Tillämpad materialvetenskap
Thomsen, Peter, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
Wiley, 2009
2009
Engelska.
Ingår i: Journal of biomedical materials research. Part B, Applied biomaterials. - : Wiley. - 1552-4981 .- 1552-4973. ; 91:1, s. 309-19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to evaluate the bone response to commercially pure titanium grade I and titanium alloy grade V (90% Ti, 6% Al, and 4% V, depicted Ti6Al4V) after 8 weeks in rabbit tibia. Interference microscopy and scanning electron microscopy were used for surface analyses. Transmission electron microscopy (TEM) was used for evaluation of surface crystallinity and chemistry after preparation of ultrathin sections using focused ion beam (FIB) microscopy. Three different embedding resins commonly used for histological preparation were evaluated with respect to adaptation to a turned implant surface. Epoxy Agar 100 resin and acrylic Technovit 7200 resin showed low separation while acrylic LR White resin showed large separation at the interface. The retrieved specimens were embedded in acrylic Technovit 7200 resin after fixation and dehydration. The histological evaluation revealed osseointegration for both c.p. titanium grade I and Ti6Al4V alloy, but no quantitative differences in bone contact and bone area were detected. Because a separation of implant and tissue occurred in the interface between implant and bone embedded in acrylic Technovit 7200 resin, additional factors related to implant surface properties and technical procedures are likely to influence the possibilities to prepare ultrathin sections by FIB.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Animals
Bone and Bones
cytology
metabolism
Coated Materials
Biocompatible
chemistry
Epoxy Resins
chemistry
Female
Implants
Experimental
Materials Testing
Osseointegration
Rabbits
Surface Properties
Titanium
chemistry
titanium
TECHNOLOGY

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy