SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/117587"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/117587" > A practical approac...

A practical approach to prioritise among optimisation tasks in X-ray imaging: introducing the 4-bit concept

Hansson, Jonny (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Sund, Patrik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Jonasson, Pernilla (författare)
visa fler...
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
2010-02-24
2010
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 393-399
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • According to European and national legislation, as well as international recommendations, X-ray examinations shall be optimised. However, with limited resources and hundreds of different types of X-ray examinations, it may be difficult to prioritise among the optimisation tasks at a radiology department. This work is focused on describing a method that can be used to determine the order of which the examinations should be optimised. In the Medical Exposure Directive from 1997, the European Commission prescribes the content of an optimisation process in relation to medical exposure. A reasonable interpretation of the directive is that the assurance of medical purpose for a justified examination is superior to the need of decreased radiation dose. This was used as a basis for developing a method for prioritisation among optimisation tasks. For each examination type, the following four yes/no questions are raised: (i) Is the present image quality unacceptable? (ii) Is the examination of particular importance? (iii) Is the radiation dose suspiciously high? (iv) Are there special dose level concerns, e.g. diagnostic reference levels? Arguing that a positive response to any of the four questions results in the examination being higher prioritised than otherwise and that the questions are labelled in order of decreasing relevance, it can be shown that the resulting flow chart, determining the order of which the examinations should be optimised, can be described by a 4-bit binary scale. In this way, each examination type is given a number from 0 to 15, a higher number corresponding to the examination being prioritised higher in the optimisation work. The method was applied to a general radiology department and resulted in a well-discriminated distribution of examinations prioritised for optimisation tasks. In conclusion, taking into account both medical outcome and potential risk, the proposed method can be used to determine the order in which examinations at a radiology department should be optimised.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy