Investigation of the effect of ambient lighting on contrast sensitivity using a novel method for conducting visual research on LCDs

Sund, Patrik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2010-03-08
2010
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 62-70
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The DICOM part 14 greyscale standard display function provides one way of harmonising image appearance under different monitor luminance settings. This function is based on ideal observer conditions, where the eye is always adapted to the target luminance and thereby also at peak contrast sensitivity. Clinical workstations are, however, often submitted to variations in ambient light due to a sub-optimal reading room light environment. Also, clinical images are inhomogeneous and low-contrast patterns must be detected even at luminance levels that differ from the eye adaptation level. All deviations from ideal luminance conditions cause the observer to detect patterns with reduced eye sensitivity but the magnitude of this reduction is unclear. A method is presented to display well-defined sinusoidal low-contrast test patterns on an liquid crystal display. The observers were exposed to light from three different areas: (i) the test pattern covering approximately 2 degrees x 2 degrees ; (ii) the remaining of the display surface and (iii) ambient light from outside the display area covering most of the observers' field of view. By adjusting the luminance from each of these three areas, the observers' ability to detect low-contrast patterns under sub-optimal viewing conditions was studied. Ambient light from outside the display area has a moderate effect on the contrast threshold, except for the combination of high ambient light and dark objects, where the contrast threshold increased considerably.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sund, Patrik
Båth, Magnus, 19 ...
Månsson, Lars Gu ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy