Monte Carlo simulations of the dosimetry of chest tomosynthesis

Svalkvist, Angelica (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2010-03-03
2010
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 144-152
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aims of this work were to explore the dosimetry of chest tomosynthesis and to determine conversion factors between air kerma-area product (KAP) and the effective dose for different system configurations and patient sizes. Tomosynthesis systems were modelled with different angular intervals and tube voltages for the collection of the projection images as well as different distributions of the total exposure over the projections. The Monte Carlo-based computer software PCXMC developed by STUK (Radiation and Nuclear Safety Authority in Finland) was used to calculate the effective doses for each modelled tomosynthesis system for various patient sizes. The conversion factor between KAP and effective dose was obtained both for the zero-degree projection alone and for the entire tomosynthesis examination for each system configuration and patient size. The results reveal that the conversion factor for the zero-degree projection can be used to estimate the total effective dose from a tomosynthesis examination with acceptable accuracy, leading to an error smaller than 10 % irrespective of the system configuration and patient size. For higher accuracy, conversion factors between the total KAP and the total effective dose that take the angular interval and exposure configuration into account are presented for each system.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Svalkvist, Angel ...
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy