Clinical performance of a ventricular automatic capture verification algorithm.

Sperzel, Johannes (författare)
Kennergren, Charles, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för kirurgi,Institute of Surgical Sciences, Department of Surgery
Biffi, Mauro (författare)
visa fler...
Smith, Mitchell (författare)
Knops, Marie (författare)
Gill, Jaswinder (författare)
Boland, Jean (författare)
visa färre...
 (creator_code:org_t)
Wiley, 2005
2005
Engelska.
Ingår i: Pacing and clinical electrophysiology : PACE. - : Wiley. - 0147-8389 .- 1540-8159. ; 28:9, s. 933-7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: This study was conducted to evaluate the clinical performance of the ventricular automatic capture feature as implemented in the Insignia I Ultra pacemaker system (Guidant) utilizing a variety of ventricular leads. Currently, the optimal programming of the pacemaker output considers both pacemaker efficiency (prolonging battery longevity) and patient safety (adequate safety margin). The ability of a pacemaker to automatically adjust the ventricular output above the pacing threshold while maintaining the appropriate safety margin has been explored since the early 1970s and is only available today in conjunction with a specific low polarization lead system. METHODS: One hundred and five patients were enrolled from 17 European centers utilizing 31 different types of ventricular leads were followed through their 3-month follow-up visit. There were no restrictions on the type of ventricular leads used. RESULTS: The average mean difference between the commanded autothreshold test (0.652 + 0.335 V) and the manual threshold test (0.651 + 0.335 V) was 0.001 + 0.49 (P < 0.0001). The average mean difference between the ambulatory autothreshold test (0.696 + 0.322 V) and the commanded autothreshold test (0.682 + 0.315 V) was 0.002 + 0.74 (P < 0.0001). Holter recordings confirmed that there were no loss of capture incidences without a backup pulse being delivered. In addition, the mean number of backup pulses delivered in a 24-hour period was less than 0.1% of the total number of paced beats. CONCLUSIONS: This study provided that the automatic capture feature while using a variety of leads accurately determines the ventricular stimulation threshold and safely delivers a backup pulse when required.

Nyckelord

Adult
Aged
Aged
80 and over
Algorithms
Electrocardiography
Ambulatory
Female
Heart Ventricles
Humans
Male
Middle Aged
Pacemaker
Artificial
Prospective Studies
Telemetry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy