SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/126785"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/126785" > An experimental eva...

An experimental evaluation of a new craniofacial implant using the rabbit tibia model: part I. Histologic findings.

Gottlow, Jan, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Sennerby, Lars, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Rosengren, Agneta (författare)
visa fler...
Flynn, Mark (författare)
visa färre...
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. - 1537-4505. ; 31:5, s. 832-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • HYPOTHESIS: This experimental study was undertaken to test the hypothesis that a new design of craniofacial implant shows a stronger tissue response than the currently used implant. MATERIALS AND METHODS: A total of 60 newly designed Cochlear Baha BI300 titanium implants (test) and 60 of the current design (control) were placed in the tibiae of 30 adult loop-eared rabbits. The new implant had the surface modified by blasting with TiO2 particles to give a moderately rough surface topography. The control implant had an as-machined surface. The animals were euthanized after 5, 14, or 28 days. The implants with surrounding bone tissue were retrieved for descriptive histology and morphometric measurements of bone-implant contacts (BICs). RESULTS: The test implants showed integration through bone formation direct on the surface and ingrowth from the vicinity. Conversely, the control implants showed increased BICs because of ingrowth of bone from the adjacent bone surfaces only. The test implant showed significantly more BICs at all time points. CONCLUSION: It is concluded that the new craniofacial implant with a moderately rough surface showed integration through a contact-osteogenesis pathway, whereas the smoother control surface was integrated by distance osteogenesis. More bone contacts were seen for test implants and, thus, a stronger bone tissue response compared with control implants. Biomechanical tests are needed to also evaluate the impact of the different histologic responses on implant stability.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gottlow, Jan, 19 ...
Sennerby, Lars, ...
Rosengren, Agnet ...
Flynn, Mark
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Otology & neurot ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy