An experimental evaluation of a new craniofacial implant using the rabbit tibia model: Part II. Biomechanical findings.

Sennerby, Lars, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Gottlow, Jan, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Rosengren, Agneta (författare)
visa fler...
Flynn, Mark (författare)
visa färre...
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. - 1537-4505. ; 31:5, s. 840-5
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • HYPOTHESIS: This experimental study was undertaken to test the hypothesis that a new design of a craniofacial implant is more stable and shows faster integration than the currently used implant. MATERIALS AND METHODS: A total of 60 newly designed Cochlear Baha titanium implants (test) and 60 of the current design (control) were placed in the tibiae of 30 adult loop-eared rabbits. The animals were euthanized after 5, 14, or 28 days. The stability of the implants was measured with Implant Stability Quotient measurements and removal torque (RTQ) tests. The Student's t test for paired statistics were used for comparisons and a difference considered if p < 0.05. RESULTS: The test implants showed a significantly higher RTQ at all time points and a steeper increase with time than the controls. The RTQ values were 19.0 (standard deviation [SD], 9.1) and 9.8 (SD, 5.6) Ncm for test and control implants, respectively, after 5 days; 27.6 (SD, 9.6) and 11.2 (SD, 3.9) Ncm after 14 days; and 43.3 (SD, 9.6) and 20.7 (SD, 14.1) Ncm after 28 days. Higher Implant Stability Quotient values were measured for the test implant at all time points. Calculations of shear stress to compensate for implant diameter revealed significantly higher values for test than for control implants after 14 and 28 days. CONCLUSION: It is concluded that the new craniofacial implant was more stable and showed a faster integration than the currently used implant. The data from the present study suggest that the new implant may be suitable for early loading protocols.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sennerby, Lars, ...
Gottlow, Jan, 19 ...
Rosengren, Agnet ...
Flynn, Mark
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Otology & neurot ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy