SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/129546"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/129546" > Marginal Bone Level...

Marginal Bone Level Changes at Dental Implants after 5 Years in Function: A Meta-Analysis.

Laurell, Lars, 0 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Lundgren, Dan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
 (creator_code:org_t)
2011-02-03
2011
Engelska.
Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ABSTRACT Background: It is important that peri-implant bone breakdown caused by, for example, undue load and/or peri-implantitis, is prevented or minimized. Some continuous loss of marginal bone is generally accepted, but the question remains as to what extent it must occur. Purpose: The purpose of this study was to compile and compare data on peri-implant marginal bone level changes from prospective studies that have registered the peri-implant marginal bone level radiographically at the time of prosthetic loading, and after 5 years of follow-up for implant systems currently available on the market. Materials and Methods: A literature search was carried out to identify prospective studies on peri-implant marginal bone level changes around dental implants. To be included in a meta-analysis, the implant systems should have been subjected to at least two independent studies. Copycats without documentation were not accepted. Results: Forty prospective studies that presented with a 5-year data were identified. Three implant systems met the inclusion criteria of having at least two independent studies; Astra Tech Dental Implant System(R) (Astra Tech AB, Mölndal, Sweden), Brånemark System (Nobel Biocare AB, Göteborg, Sweden), and Straumann Dental Implant System (Institute Straumann AG, Basel, Switzerland). The pooled mean marginal bone level change amounted to -0.24 mm (95% CI -0.345, -0.135) for the Astra Tech Dental Implant System, 0.75 mm (95% CI -0.802, -0.693) for the Brånemark System, and 0.48 mm (95% CI -0.598, -0.360) for the Straumann Dental Implant System over 5 years, with a statistically significant difference (p < .01) between the systems. Conclusions: The identified implant systems showed an annual bone loss below or much below what hitherto has been set up as a limit for success. A careful documentation of marginal bone level changes should be mandatory for all implant systems before being marketed. It is also time for revision of existing success criteria to refine the basis for clinical quality judgment of implant treatment.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Laurell, Lars, 0
Lundgren, Dan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Clinical implant ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy