Sökning: id:"swepub:oai:gup.ub.gu.se/129561" >
Direct loading of N...
Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a 1-year prospective clinical and radiographic study.
-
- Östman, Pär-Olov, 1968 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
-
- Hellman, Mats (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
-
- Albrektsson, Tomas, 1945 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
-
visa fler...
-
- Sennerby, Lars, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
-
visa färre...
-
(creator_code:org_t)
- Wiley, 2007
- 2007
- Engelska.
-
Ingår i: Clinical oral implants research. - : Wiley. - 0905-7161 .- 1600-0501. ; 18:4, s. 409-18
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVES: The aim of this prospective study was to evaluate the Nobel Direct and Nobel Perfect one-piece implants (OPIs) when used for immediate function. MATERIAL AND METHODS: Forty-eight patients were provided with 115 OPIs for loading with a provisional crown or a bridge within 24 h and followed for at least 12 months with clinical and radiographic examinations. A group of 97 patients previously treated under identical conditions by the same team with 380 two-piece implants (TPIs) for immediate loading in the mandible and maxilla served as the reference group. RESULTS: Six (5.2%) OPIs failed during the follow-up due to extensive bone loss. Five (1.3%) implants failed in the reference group. After 1 year, the mean marginal bone loss was 2.1 mm (SD 1.3) for OPIs and 0.8 mm (SD 1) for TPIs. 20% of OPIs showed more than 3 mm of bone loss compared with 0.6% for TPIs. When compensating for vertical placement depth, OPIs still showed a lower marginal bone level and thus more exposed threads than TPIs. Depending on the criteria used, the success rate for OPIs was 46.1% or 72.2% compared with 85% or 91.6% for TPIs. CONCLUSIONS: The Nobel Direct and Nobel Perfect OPIs show lower success rates and more bone resorption than TPIs after 1 year in function. Factors such as implant design, insertion depth, rough surface towards the mucosa, in situ preparation and immediate loading may have an influence on the clinical outcome.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Aged
- Alveolar Bone Loss
- etiology
- Dental Implantation
- Endosseous
- Dental Implants
- adverse effects
- Dental Prosthesis Design
- adverse effects
- Dental Prosthesis
- Implant-Supported
- Dental Restoration Failure
- Dental Stress Analysis
- Denture
- Partial
- Immediate
- Female
- Humans
- Jaw
- Edentulous
- Partially
- radiography
- Male
- Middle Aged
- Prospective Studies
Publikations- och innehållstyp
- vet (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas