SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/132232"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/132232" > Changes in electroc...

Changes in electrocardiographic left ventricular hypertrophy and risk of major cardiovascular events in isolated systolic hypertension: The LIFE study

Larstorp, A. C. (författare)
Okin, P. M. (författare)
Devereux, R. B. (författare)
visa fler...
Olsen, M. H. (författare)
Ibsen, H. (författare)
Dahlöf, Björn, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
Kjeldsen, S. E. (författare)
Wachtell, K. (författare)
visa färre...
 (creator_code:org_t)
2011
2011
Engelska.
Ingår i: Journal of Human Hypertension. - 0950-9240. ; 25:3, s. 178-185
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The predictive value of changes in the severity of electrocardiographic left ventricular hypertrophy (ECG-LVH) during antihypertensive therapy remains unclear in isolated systolic hypertension (ISH). In a Losartan Intervention For Endpoint reduction in hypertension substudy, we included 1320 patients aged 54-83 years with systolic blood pressure (BP) of 160-200 mm Hg, diastolic BP <90 mm Hg and ECG-LVH by Cornell voltage-duration product and/or Sokolow-Lyon voltage criteria, randomized to losartan- or atenolol-based treatment with a mean follow-up of 4.8 years. The composite end point of cardiovascular death, non-fatal myocardial infarction (MI) or stroke occurred in 179 (13.6%) patients. In Cox regression models controlling for treatment, Framingham risk score, as well as baseline and in-treatment BP, less severe in-treatment ECG-LVH by Cornell product and Sokolow-Lyon voltage was associated with 17 and 25% risk reduction for the composite end point (adjusted hazard ratio (HR) 0.83, 95% confidence interval (95% CI:) 0.75-0.92, P=0.001 per 1050 mm x ms (1 s.d.) lower Cornell product; and HR 0.75, 95% CI: 0.65-0.87, P<0.001 per 10.5 mm (1 s.d.) lower Sokolow-Lyon voltage). In parallel analyses, lower Cornell product and Sokolow-Lyon voltage were associated with lower risks of cardiovascular mortality and MI, and lower Sokolow-Lyon voltage with lower risk of stroke. Lower Cornell product and Sokolow-Lyon voltage during antihypertensive therapy are associated with lower likelihoods of cardiovascular events in patients with ISH.Journal of Human Hypertension advance online publication, 27 May 2010; doi:10.1038/jhh.2010.52.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

ageing; cardiovascular diseases; electrocardiography; hypertrophy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy