The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study.

Örtorp, Anders, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Jönsson, David (författare)
Mouhsen, Alaa (författare)
visa fler...
Vult von Steyern, Per (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Jönsson, Daniel (författare)
Malmö högskola,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Dental materials. - : Elsevier BV. - 1879-0097 .- 0109-5641. ; 27:4, s. 356-363
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: This study sought to evaluate and compare the marginal and internal fit in vitro of three-unit FDPs in Co-Cr made using four fabrication techniques, and to conclude in which area the largest misfit is present. METHODS: An epoxy resin master model was produced. The impression was first made with silicone, and master and working models were then produced. A total of 32 three-unit Co-Cr FDPs were fabricated with four different production techniques: conventional lost-wax method (LW), milled wax with lost-wax method (MW), milled Co-Cr (MC), and direct laser metal sintering (DLMS). Each of the four groups consisted of eight FDPs (test groups). The FDPs were cemented on their cast and standardised-sectioned. The cement film thickness of the marginal and internal gaps was measured in a stereomicroscope, digital photos were taken at 12× magnification and then analyzed using measurement software. Statistical analyses were performed with one-way ANOVA and Tukey's test. RESULTS: Best fit based on the means (SDs) in μm for all measurement points was in the DLMS group 84 (60) followed by MW 117 (89), LW 133 (89) and MC 166 (135). Significant differences were present between MC and DLMS (p<0.05). The regression analyses presented differences within the parameters: production technique, tooth size, position and measurement point (p<0.05). SIGNIFICANCE: Best fit was found in the DLMS group followed by MW, LW and MC. In all four groups, best fit in both abutments was along the axial walls and in the deepest part of the chamfer preparation. The greatest misfit was present occlusally in all specimens.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Accuracy; Cement film thickness; Marginal gaps; Discrepancies; Fabrication techniques

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy