SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/144089"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/144089" > A method to analyse...

A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT images.

Ledenius, Kerstin, 1979 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Dept Radiat Phys, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Univ Gothenburg, Gothenburg, Sweden
Svensson, Elisabeth (författare)
Örebro universitet,Handelshögskolan vid Örebro universitet
Stålhammar, F (författare)
Dept Paediat Radiol & Physiol, Queen Silvia Childrens Hosp, Gothenburg, Sweden
visa fler...
Wiklund, Lars-Martin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics,Dept Paediat Radiol & Physiol, Queen Silvia Childrens Hosp, Gothenburg, Sweden
Thilander-Klang, Anne, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Dept Radiat Phys, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Univ Gothenburg, Gothenburg, Sweden; Dept Med Phys & Biomed Engn, Sahlgrenska Univ Hosp, Gothenburg, Sweden
visa färre...
 (creator_code:org_t)
British Institute of Radiology, 2010
2010
Engelska.
Ingår i: The British journal of radiology. - : British Institute of Radiology. - 1748-880X .- 0007-1285. ; 83:991, s. 604-11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose was to demonstrate a non-parametric statistical method that can identify and explain the components of observer disagreement in terms of systematic disagreement as well as additional individual variability, in visual grading studies. As an example, the method was applied to a study where the effect of reduced tube current on diagnostic image quality in paediatric cerebral multidetector CT (MDCT) images was investigated. Quantum noise, representing dose reductions equivalent to steps of 20 mA, was artificially added to the raw data of 25 retrospectively selected paediatric cerebral MDCT examinations. Three radiologists, blindly and randomly, assessed the resulting images from two different levels of the brain with regard to the reproduction of high- and low-contrast structures and overall image quality. Images from three patients were assessed twice for the analysis of intra-observer disagreement. The intra-observer disagreement in test-retest assessments could mainly be explained by a systematic change towards lower image quality the second time the image was reviewed. The inter-observer comparisons showed that the paediatric radiologist was more critical of the overall image quality, while the neuroradiologists were more critical of the reproduction of the basal ganglia. Differences between the radiologists regarding the extent to which they used the whole classification scale were also found. The statistical method used was able to identify and separately measure a presence of bias apart from additional individual variability within and between the radiologists which is, at the time of writing, not attainable by any other statistical approach suitable for paired, ordinal data.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
NATURVETENSKAP  -- Matematik -- Sannolikhetsteori och statistik (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Probability Theory and Statistics (hsv//eng)

Nyckelord

Adolescent
Brain
radiography
Child
Child
Preschool
Female
Humans
Infant
Infant
Newborn
Male
Neurology
Observer Variation
Pediatrics
Reproducibility of Results
Retrospective Studies
Statistics
Nonparametric
Tomography
X-Ray Computed
methods
statistics & numerical data
Statistics
Statistik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy