A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography.

Johnsson, Åse (Allansdotter), 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Svalkvist, Angelica (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Vikgren, Jenny, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
visa fler...
Boijsen, Marianne, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Flinck, Agneta, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Kheddache, Susanne, 1949 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
2010-02-04
2010
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 140-143
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Algorithms
Humans
Lung Neoplasms
radiography
Phantoms
Imaging
Radiographic Image Enhancement
methods
Radiographic Image Interpretation
Computer-Assisted
methods
Radiography
Thoracic
methods
Reproducibility of Results
Sensitivity and Specificity
Solitary Pulmonary Nodule
radiography
Tomography
X-Ray Computed
methods

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy