A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.
-
- Jemt, Torsten, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
- Henry, Patrick (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
- Lindén, Bengt, 1956 (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
visa fler...
-
- Naert, Ignace (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
- Weber, Heiner (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
- Bergström, C (författare)
- Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
-
visa färre...
-
(creator_code:org_t)
- 2000
- 2000
- Engelska.
-
Ingår i: The International journal of prosthodontics. - 0893-2174. ; 13:4, s. 282-8
- Relaterad länk:
-
https://gup.ub.gu.se...
Abstract
Ämnesord
Stäng
- PURPOSE: The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. MATERIALS AND METHODS: Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. RESULTS: Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. CONCLUSION: The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Adolescent
- Adult
- Aged
- Alveolar Bone Loss
- diagnosis
- Chi-Square Distribution
- Dental Casting Technique
- Dental Prosthesis
- Implant-Supported
- Dental Restoration Failure
- Dental Soldering
- instrumentation
- Dental Veneers
- Denture Design
- Denture
- Partial
- Fixed
- Female
- Humans
- Jaw
- Edentulous
- Partially
- rehabilitation
- Lasers
- Life Tables
- Male
- Middle Aged
- Prospective Studies
- Statistics
- Nonparametric
- Titanium
- Welding
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek