Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits.

Jemt, Torsten, 1950 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Lekholm, Ulf, 1944 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen, Avdelningen för oral och maxillofacial kirurgi,Institute of Odontology, Department of Oral and Maxillofacial Surgery
 (creator_code:org_t)
2001-12-25
1998
Engelska.
Ingår i: Clinical oral implants research. - : Wiley. - 0905-7161. ; 9:4, s. 272-80
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This in vivo study used a 3-D photogrammetric technique to measure distortion of 3 unit implant frame-works and bone surrounding osseointegrated implants after securing misfitting superstructures to the implants. Four adult loop-eared rabbits were provided with 3 implants each in the proximal part of 1 tibia each. After a healing period of 8 weeks, a titanium frame-work was connected with a misfit to the central implant. Three-dimensional photographs were taken before and after securing the central screw, which induced a calculated mean preload of 246 N. Measurements and comparisons of the topography of the frame-works and surrounding bone before and after tightening the central screw indicated a complex and inconsistent deformation pattern. Generally, it could be observed that the top edge of the central cylinder showed vertical movement towards the bone of about 150 microns, always in combination with a rotation of the entire super-structure. The head of the central implant seemed to show a corresponding displacement towards the frame-work of about 50 to 200 microns. Bone deformation was found to be basically localized between the implants, where compressions of about half a millimetre were observed. This concentration of bone deformation as a result of misfit may be one contributing factor to initial marginal bone loss, occasionally observed after insertion of implant supported prostheses.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Animals
Bone Remodeling
Dental Implants
adverse effects
Image Processing
Computer-Assisted
Implants
Experimental
adverse effects
Photogrammetry
Pilot Projects
Prosthesis Fitting
Rabbits
Stress
Mechanical
Tibia
Torque
Weight-Bearing

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jemt, Torsten, 1 ...
Lekholm, Ulf, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Clinical oral im ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy