SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/154337"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/154337" > On the formation of...

On the formation of fibrous capsule and fluid space around machined and porous blood plasma clot coated titanium.

Jansson, E (författare)
Källtorp, Mia (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institutionen för anatomi och cellbiologi,Institute of Surgical Sciences, Department of Biomaterials,Institute of Anatomy and Cell Biology
Johansson, Anna, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
visa fler...
Tengvall, Pentti (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
Thomsen, Peter, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: Journal of materials science. Materials in medicine. - 0957-4530. ; 12:10-12, s. 1019-24
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Machined and machined submicron porous titanium, with and without a thin blood plasma coating (100 nm), were implanted for 7 or 28 days in subcutaneous pockets on the back of the rat. After explantation the specimens were analyzed by light microscopy with respect to thickness of the fibrous capsule, the fluid space width between implants and fibrous capsule, and formation of blood vessels. The results at 7 days indicate a thinnest fluid space for the plasma clot coated porous titanium surface, and the spaces vanished at the light microscopic level after 28 days outside all the analyzed surfaces. The thickness of the fibrous capsule increased outside the different surfaces at 7-28 days, and in this respect no significant differences were observed between the different surfaces at any time. Analysis of neovascularization showed that the number of vessels and proportion of vessels in the fibrous capsule increased with time at all surfaces, except machined Ti where the number instead decreased from 7 to 28 days. The average distance between the blood vessels and the fluid space increased with time for all types of surfaces. The results in the present study indicate that the healing process around titanium can be modulated by porosity and thin pre-prepared plasma coatings.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jansson, E
Källtorp, Mia
Johansson, Anna, ...
Tengvall, Pentti
Thomsen, Peter, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinsk biotek ...
och Biomaterialveten ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Journal of mater ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy