Sökning: id:"swepub:oai:gup.ub.gu.se/158373" >
Are intravenous inj...
Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?
-
- Nyman, Ulf (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
-
- Almén, Torsten (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
-
- Jacobsson, Bo, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
-
visa fler...
-
- Aspelin, P. (författare)
- Karolinska Institutet
-
visa färre...
-
(creator_code:org_t)
- 2012-02-04
- 2012
- Engelska.
-
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 22:6, s. 1366-1371
- Relaterad länk:
-
https://link.springe...
-
visa fler...
-
http://www.ncbi.nlm....
-
http://dx.doi.org/10...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since 1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, 2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, 3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, 4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, 5) roughly the same gram-iodine/GFR ratio (a parts per thousand 1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and 6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points Most intra-arterial injections of contrast media are intravenous relative to the kidneys. No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Angiography
- Acute kidney injury
- Computed tomography
- Contrast media
- Renal insufficiency
Publikations- och innehållstyp