Accuracy of quantitative magnetic resonance and eight-electrode bioelectrical impedance analysis in normal weight and obese women.

Bosaeus, Marja (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology
Karlsson, Therese, 1979 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för fysiologi,Institute of Neuroscience and Physiology, Department of Physiology
Holmäng, Agneta, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology
visa fler...
Ellegård, Lars, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition
visa färre...
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Clinical Nutrition. - : Elsevier BV. - 0261-5614. ; 33:3, s. 471-477
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background & aims Quantitative magnetic resonance (QMR) has previously been shown to both overestimate and underestimate average fat mass (FM) in humans. Eight-electrode bioelectrical impedance analysis (BIA) has previously been found biased as well as successfully validated. We report cross-sectional accuracy of QMR and eight-electrode BIA evaluated with air displacement plethysmography (ADP) as reference method. Methods Fat mass and fat free mass (FFM) by QMR and eight-electrode BIA were evaluated against ADP as reference in 38 normal weight and 30 obese women. Total body water estimates by QMR and eight-electrode BIA were compared. Results Fat mass was overestimated by QMR (1 ± 2 kg, p < 0.001) and was underestimated by eight-electrode BIA (1 ± 3 kg, p = 0.03, Bonferroni adjusted p = 0.29) in normal weight women. Fat mass was underestimated by both QMR (2 ± 2 kg, p < 0.001) and eight-electrode BIA (9 ± 3 kg, p < 0.001) in obese women. Fat free mass biases were of similar magnitude but in opposite direction to FM biases. Total body water estimates were larger by eight-electrode BIA compared to QMR (1–10 kg). Conclusions Fat mass and FFM by QMR were both biased but in opposite directions in both normal weight and obese women. Eight-electrode BIA FM and FFM estimates were imprecise and biased in obese women. Thus, QMR is more precise and more accurate than eight-electrode BIA for estimating body composition in women, but is not accurate enough to be used for individual single assessment of body composition.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

body composition
obesity
quantitative magnetic resonance
bioelectrical analysis
air displacement pletysmography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy