SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/199386"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/199386" > Improving multiphot...

Improving multiphoton microscopy using annular beam shaping, focusing on imaging of human skin

Borglin, Johan, 1986 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Institutionen för fysik (GU),Department of Chemistry and Molecular Biology,Department of Physics (GU)
Durr, N.J. (författare)
Guldbrand, Stina, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
visa fler...
Ferhanoǧlu, O. (författare)
Wennberg, Ann-Marie, 1956 (författare)
Hanstorp, Dag, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
Ben-Yakar, A. (författare)
Ericson, Marica B, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology
visa färre...
 (creator_code:org_t)
SPIE, 2014
2014
Engelska.
Ingår i: Multiphoton Microscopy in the Biomedical Sciences XIV: 2-4 February 2014, San Francisco, California, United States. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 8948
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Multiphoton fluorescence microscopy (MPM) is a method for high resolution, non-invasive investigations of biological tissue. The aim of introducing an annular shaped laser beam is to reduce the ouf-of-focus generated background signal improving imaging of light scattering tissue such as human skin. Simulations show that 50% of the beam radius can be blocked, while preserving the shape of the point spread function. Initial experiments performed on a phantom consisting of fluorescein and fluorescent beads embedded in agar by using a custom built MPM-set up show that by introducing a simple beam blocker to create an annular beam, the background signal is reduced with approximately 5%. Future work will include optimizing the set up, and creating phantoms with more light scattering properties. © 2014 SPIE.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

annular beams
Bessel beams
Multiphoton miocroscopy
two photon microscopy

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy