Sökning: id:"swepub:oai:gup.ub.gu.se/207251" >
Evaluation of the i...
Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures
-
- Sandblom, Viktor, 1987 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
- Mai, Tu, 1987 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
Almén, Anja, 1964 (författare)
-
visa fler...
-
- Rystedt, Hans, 1951 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för pedagogik, kommunikation och lärande,Department of Education, Communication and Learning
-
- Cederblad, Åke, 1947 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
- Båth, Magnus, 1974 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
- Lundh, Charlotta, 1977 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
visa färre...
-
(creator_code:org_t)
- 2013
- 2013
- Engelska.
-
Ingår i: Nationellt möte om sjukhusfysik 2013, 13-14 november 2013, Varberg.
- Relaterad länk:
-
https://gup.ub.gu.se...
Abstract
Ämnesord
Stäng
- Optimisation of radiological protection for operators working with fluoroscopically guided procedures has to be performed during the procedure, under varying and difficult conditions. The aim of this study was to evaluate the impact of a system for real-time visualisation of radiation dose rate on optimisation of occupational radiological protection during fluoroscopically guided procedures. Individual radiation dose measurements, using a system for real-time visualisation, were performed in a cardiology laboratory for three cardiologists and ten assisting nurses. Radiation doses collected when the radiation dose rates were not displayed to the staff (period 1) were compared to radiation doses collected when the radiation dose rates were displayed (period 2). The results showed that when the radiation dose rates were displayed to the staff, one cardiologist and the assisting nurses (as a group) significantly reduced their personal radiation doses. The median radiation dose ((Hp(10)) per procedure decreased from 68 to 28 μSv (p=0.003) for this cardiologist and from 4.3 to 2.5 μSv (p=0.001) for the assisting nurses. The results of the present study indicate that a system for real-time visualisation of radiation dose rate may have a positive impact on optimisation of occupational radiological protection. In particular, this may affect the behaviour of staff members practising inadequate personal radiological protection.
Ämnesord
- SAMHÄLLSVETENSKAP -- Utbildningsvetenskap -- Pedagogik (hsv//swe)
- SOCIAL SCIENCES -- Educational Sciences -- Pedagogy (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- vet (ämneskategori)
- kon (ämneskategori)
- Av författaren/redakt...
-
Sandblom, Viktor ...
-
Mai, Tu, 1987
-
Almén, Anja, 196 ...
-
Rystedt, Hans, 1 ...
-
Cederblad, Åke, ...
-
Båth, Magnus, 19 ...
-
visa fler...
-
Lundh, Charlotta ...
-
visa färre...
- Om ämnet
-
- SAMHÄLLSVETENSKAP
-
SAMHÄLLSVETENSKA ...
-
och Utbildningsveten ...
-
och Pedagogik
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
- Nationellt möte ...
- Av lärosätet
-
Göteborgs universitet