SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/208104"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/208104" > Evaluation of a Sen...

Evaluation of a Sensitive Copeptin Assay for Clinical Measurement

Hammarsten, Ola (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Terzic, D (författare)
goetze, jens (författare)
visa fler...
Johansson-Fällgren, A. S. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Ragnarsson, Oskar, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine
visa färre...
 (creator_code:org_t)
Bentham Science Publishers Ltd. 2012
2012
Engelska.
Ingår i: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 21-26
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Abstract: Background: Copeptin, a marker of vasopressin production, has been introduced for earlier diagnosis of acute myocardial infarction and other clinical emergencies. We evaluated the analytical performance of a new generation copeptin assay in an inter-laboratory trial. Methods: Precision, linearity range, carry-over contamination, the limit of blank and an inter-laboratory comparison trial for the copeptin US KRYPTOR assay were performed on the B·R·A·H·M·S KRYPTOR compact PLUS. Results: The intra-assay imprecision (CVs) was 12.6–2.2% and total imprecision over five days was 12.3-4.3% between 3.1 and 18.2 pmol/L. The assay had excellent linearity between 7-222 pmol/L. The limit of blank was 2.5 pmol/L and the limit of detection was 3.2 pmol/L, but was dependent on the analyte-free material used. No significant difference between sample type, such as serum or different types of plasma or reagent lots, was noted. The copeptin results remained unchanged upon five repeated freeze-thaw cycles. A set of patient samples with a mean copeptin concentration of 2.1-61 pmol/L run at two separate sites showed close correlation (r2=0.99, slope=1.01, intercept=0.35), indicating comparable results across laboratories. Conclusion: The new ultrasensitive copeptin KRYPTOR assay shows excellent inter-lab precision, opening up the possibility for international guidelines to exclude acute myocardial infarction.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Nyckelord

Copeptin
diabetes insipidus
myocardial infarction
heart failure
vasopressin

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hammarsten, Ola
Terzic, D
goetze, jens
Johansson-Fällgr ...
Ragnarsson, Oska ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Endokrinologi oc ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
Artiklar i publikationen
The Open Clinica ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy