Intracranial pressure in hydrocephalus: impact of shunt adjustments and body positions

Farahmand, Dan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology,Hydrocephalus Research Unit, Institute of Neuroscience and Physiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
Qvarlander, Sara, 1982- (författare)
Umeå universitet,Radiofysik
Malm, Jan (författare)
Umeå universitet,Klinisk neurovetenskap
visa fler...
Wikkelsö, Carsten, 1947 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology,Hydrocephalus Research Unit, Institute of Neuroscience and Physiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
Eklund, Anders (författare)
Umeå universitet,Radiofysik
Tisell, Magnus, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology,Hydrocephalus Research Unit, Institute of Neuroscience and Physiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
visa färre...
 (creator_code:org_t)
2014-06-24
2015
Engelska.
Ingår i: Journal of Neurology Neurosurgery and Psychiatry. - : BMJ. - 0022-3050 .- 1468-330X. ; 86:2, s. 222-228
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background The association between intracranial pressure (ICP) and different shunt valve opening pressures in relation to body positions is fundamental for understanding the physiological function of the shunt. Objective To analyse the ICP and ICP wave amplitude (AMP) at different shunt settings and body positions in patients with hydrocephalus. Methods In this prospective study 15 patients with communicating hydrocephalus were implanted with a ligated adjustable ventriculoperitoneal shunt. They also received a portable intraparenchymatous ICP-monitoring device. Postoperative ICP and AMP were recorded with the patients in three different body positions (supine, sitting and walking) and with the shunt ligated and open at high, medium and low valve settings. In each patient 12 10 min segments were coded, blinded and analysed for mean ICP and mean AMP using an automated computer algorithm. Results Mean ICP and mean AMP were lower at all three valve settings compared with the ligated shunt state (p<0.001). Overall, when compared with the supine position, mean ICP was 11.5 +/- 1.1 (mean +/- SD) mm Hg lower when sitting and 10.5 +/- 1.1 mm Hg lower when walking (p<0.001). Mean ICP was overall 1.1 mm Hg higher (p=0.042) when walking compared with sitting. The maximal adjustability difference (highest vs lowest valve setting) was 4.4 mm Hg. Conclusions Changing from a supine to an upright position reduced ICP while AMP only increased at trend level. Lowering of the shunt valve opening pressure decreased ICP and AMP but the difference in mean ICP in vivo between the highest and lowest opening pressures was less than half that previously observed in vitro.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

VALVE OPENING PRESSURE
FLUID PULSE PRESSURE
CLINICAL-EVALUATION
TECHNICAL REPORT
BRAINIT GROUP
DYNAMICS
PULSATILITY
MANAGEMENT
SENSORS
SYSTEM
Clinical Neurology
Psychiatry
Surgery

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy