IMPROVED PLANAR KIDNEY ACTIVITY CONCENTRATION ESTIMATE BY THE POSTERIOR VIEW METHOD IN 177LU-DOTATATE TREATMENTS.

Magnander, Tobias (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Svensson, Johanna (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences, Department of Oncology
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa fler...
Gjertsson, Peter, 1961 (författare)
Bernhardt, Peter, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
2016-03-23
2016
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 259-266
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aims of this study were to determine how different background regions of interest (ROIs) around the kidney represent true background activity in over- and underlying tissues in(177)Lu-DOTA-octreatate ((177)Lu-DOTATATE) treatments and to determine the influence of the background positions on the kidney activity concentration estimates by the conjugate view (ConjV) and posterior view (PostV) methods. The analysis was performed in single-photon emission computed tomography (SPECT) images of 20 patients, acquired 24 h post injection of a(177)Lu-DOTATATE treatment, by a computer algorithm that created planar images from the SPECT data. The ratio between the activity concentration in the background and the true background varied from 0.36 to 2.08 [coefficient of variation (CV) = 25-181 %] and from 0.44 to 1.52 (CV = 16-70 %) for the right and left kidneys, respectively. The activity concentration estimate in the kidneys was most accurate with the PostV method using a background ROI surrounding the whole kidney, and this combination might be an alternative planar method for improved kidney dosimetry in the(177)Lu-DOTATATE treatments.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy