THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER

Hansson, Jonny (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2016-03-14
2016
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 54-59
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC. For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hansson, Jonny
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy