SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/235511"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/235511" > The effect of fixed...

The effect of fixed eye adaptation when using displays with a high luminance range

Sund, Patrik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
SPIE, 2012
2012
Engelska.
Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 8318
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Calibration of medical review displays according to the part 14 Grayscale Standard Display Function (GSDF) is important in order to obtain consistency in displayed image quality since display technology and viewing conditions may vary substantially. Unfortunately, the purpose of the GSDF calibration is best suited for low luminance range conditions but is not optimal when using modern displays with a high luminance range. Low contrast objects will then obtain a greater visibility in mid-gray areas compared to similar objects in bright or dark regions. In this study, low contrast sinusoidal patterns were displayed on a high luminance range monitor under realistic viewing conditions. In order to simulate the viewing of an x-ray image with both dark and bright regions displayed simultaneously, the luminance of the patterns ranged from 2 to 600 cd/m2 while the observers were always adapted to the logarithmic average of 35 cd/m2. The results show a clear relationship between the patterns deviation from the adaptation luminance level and the necessary contrast required to detect the pattern. The results also indicate the potential for an improvement in the lowcontrast detectability over a large luminance range by adjusting the GSDF for the limited eye adaptation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sund, Patrik
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Progress in Biom ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 