SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/239790"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/239790" > Impact of region-of...

Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts

Lilja, Ylva (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Gustafsson, Oscar, 1989 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Ljungberg, Maria (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa fler...
Nilsson, Daniel, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
visa färre...
 (creator_code:org_t)
2016-07-11
2016
Engelska.
Ingår i: Bmc Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 16
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: To extract DTI parameters from a specific structure, a region of interest (ROI) must be defined. ROI selection in small structures is challenging; the final measurement results could be affected due to the significant impact of small geometrical errors. In this study the optic tracts were analyzed with the aim to assess differences in DTI parameters due to ROI method and to identify the most reliable method. Methods: Images of 20 healthy subjects were acquired. Fractional anisotropy (FA) was extracted from the optic tracts by four different ROI methods. Manual tracing was performed in 1) the b0 image and 2) a T1-weighted image registered to the FA image. Semi-automatic segmentation was performed based on 3) tractography and 4) the FA-skeleton algorithm in the tract-based spatial statistics (TBSS) framework. Results were analyzed with regard to ROI method as well as to inter-scan, intra-rater and inter-rater reliability. Results: The resulting FA values divided the ROI methods into two groups that differed significantly: 1) the FA-skeleton and the b0 methods showed higher FA values compared to 2) the tractography and the T1-weighted methods. The intra-and inter-rater variabilities were similar for all methods, except for the tractography method where the inter-rater variability was higher. The FA-skeleton method had a better reproducibility than the other methods. Conclusion: Choice of ROI method was found to be highly influential on FA values when the optic tracts were analyzed. The FA-skeleton method performed the best, yielding low variability and high repeatability.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

spatial statistics
diffusion
brain
reproducibility
tractography
images
registration
reliability
neuritis
Radiology
Nuclear Medicine & Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lilja, Ylva
Gustafsson, Osca ...
Ljungberg, Maria
Nilsson, Daniel, ...
Starck, Göran
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Bmc Medical Imag ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy