Sökning: id:"swepub:oai:gup.ub.gu.se/253332" >
A Clinical Trial of...
A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes
-
- Olafsdottir, Arndis, 1978 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,NU Hospital Grp, Sweden; University of Gothenburg, Sweden
-
- Attvall, Stig, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,Sahlgrens University Hospital, Sweden; University of Gothenburg, Sweden
-
- Sandgren, U. (författare)
- Sahlgrens University Hospital, Sweden
-
visa fler...
-
- Dahlqvist, S. (författare)
- NU Hospital Group, Uddevalla, Sweden
-
- Pivodic, A. (författare)
- Statistiska Konsultgruppen, Sweden
-
- Skrtic, Stanko, 1970 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg, Sweden; AstraZeneca Rand D, Sweden
-
- Theodorsson, Elvar (författare)
- Linköpings universitet,Avdelningen för mikrobiologi och molekylär medicin,Medicinska fakulteten,Region Östergötland, Klinisk kemi
-
- Lind, Marcus, 1976 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,NU Hospital Grp, Sweden; University of Gothenburg, Sweden
-
visa färre...
-
(creator_code:org_t)
- Mary Ann Liebert Inc, 2017
- 2017
- Engelska.
-
Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 19:3, s. 164-172
- Relaterad länk:
-
https://www.liebertp...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: In Sweden, FreeStyle Libre a flash glucose monitoring system came onto the market in 2014 as a complement to self-monitoring of blood glucose. The aim of this study was to evaluate the accuracy and treatment experience of the FreeStyle Libre system. Methods: Fifty-eight adults with type 1 diabetes used FreeStyle Libre for 10-14 days and measured capillary blood glucose levels with the HemoCue blood glucose measurement system at least six times a day simultaneously. Results: For the entire study period, the mean absolute relative difference (MARD) was 13.2% (95% confidence interval [CI] 12.0%-14.4%). MARD was 13.6% (95% CI 12.1%-15.4%) during week 1 and 12.7% (95% CI 11.5%-13.9%) during week 2. The mean absolute difference (MAD) for the whole study period was 19.8mg/dL (1.1mmol/L) (95% CI 17.8-21.8 mg/dL), including 20.5 mg/dL (1.14 mmol/L) during week 1 and 19.0 mg/dL (1.05 mmol/L) during week 2. The overall correlation coefficient was 0.96. For glucose values < 72, 72-180, and > 180mg/dL (< 4, 4-10, and > 10 mmol/L), the MARD was 20.3% (95% CI 17.7%-23.1%), 14.7% (95% CI 13.4%-16%), and 9.6% (95% CI 8.5%-10.8%), respectively, and respective MAD values were 12.3, 17.8, and 23.6 mg/dL (0.69, 0.99, and 1.31mmol/L). Using the 10-item visual analog scale, patients rated their experience with FreeStyle Libre as generally positive, with mean values ranging from 8.22 to 9.8. Conclusions: FreeStyle Libre had a similar overall MARD as continuous blood glucose monitoring systems in earlier studies when studied in similar at-home conditions. The overall patient satisfaction was high.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Nyckelord
- Diabetes mellitus
- Flash glucose monitor
- Accuracy
- randomized controlled-trial
- glycemic control
- system
- Endocrinology & Metabolism
- Diabetes mellitus; Flash glucose monitor; Accuracy
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Olafsdottir, Arn ...
-
Attvall, Stig, 1 ...
-
Sandgren, U.
-
Dahlqvist, S.
-
Pivodic, A.
-
Skrtic, Stanko, ...
-
visa fler...
-
Theodorsson, Elv ...
-
Lind, Marcus, 19 ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Endokrinologi oc ...
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Medicinsk biotek ...
-
och Biomedicinsk lab ...
- Artiklar i publikationen
-
Diabetes Technol ...
- Av lärosätet
-
Göteborgs universitet
-
Linköpings universitet