A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes

Olafsdottir, Arndis, 1978 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,NU Hospital Grp, Sweden; University of Gothenburg, Sweden
Attvall, Stig, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,Sahlgrens University Hospital, Sweden; University of Gothenburg, Sweden
Sandgren, U. (författare)
Sahlgrens University Hospital, Sweden
visa fler...
Dahlqvist, S. (författare)
NU Hospital Group, Uddevalla, Sweden
Pivodic, A. (författare)
Statistiska Konsultgruppen, Sweden
Skrtic, Stanko, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg, Sweden; AstraZeneca Rand D, Sweden
Theodorsson, Elvar (författare)
Linköpings universitet,Avdelningen för mikrobiologi och molekylär medicin,Medicinska fakulteten,Region Östergötland, Klinisk kemi
Lind, Marcus, 1976 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,NU Hospital Grp, Sweden; University of Gothenburg, Sweden
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2017
2017
Engelska.
Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert Inc. - 1520-9156 .- 1557-8593. ; 19:3, s. 164-172
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: In Sweden, FreeStyle Libre a flash glucose monitoring system came onto the market in 2014 as a complement to self-monitoring of blood glucose. The aim of this study was to evaluate the accuracy and treatment experience of the FreeStyle Libre system. Methods: Fifty-eight adults with type 1 diabetes used FreeStyle Libre for 10-14 days and measured capillary blood glucose levels with the HemoCue blood glucose measurement system at least six times a day simultaneously. Results: For the entire study period, the mean absolute relative difference (MARD) was 13.2% (95% confidence interval [CI] 12.0%-14.4%). MARD was 13.6% (95% CI 12.1%-15.4%) during week 1 and 12.7% (95% CI 11.5%-13.9%) during week 2. The mean absolute difference (MAD) for the whole study period was 19.8mg/dL (1.1mmol/L) (95% CI 17.8-21.8 mg/dL), including 20.5 mg/dL (1.14 mmol/L) during week 1 and 19.0 mg/dL (1.05 mmol/L) during week 2. The overall correlation coefficient was 0.96. For glucose values < 72, 72-180, and > 180mg/dL (< 4, 4-10, and > 10 mmol/L), the MARD was 20.3% (95% CI 17.7%-23.1%), 14.7% (95% CI 13.4%-16%), and 9.6% (95% CI 8.5%-10.8%), respectively, and respective MAD values were 12.3, 17.8, and 23.6 mg/dL (0.69, 0.99, and 1.31mmol/L). Using the 10-item visual analog scale, patients rated their experience with FreeStyle Libre as generally positive, with mean values ranging from 8.22 to 9.8. Conclusions: FreeStyle Libre had a similar overall MARD as continuous blood glucose monitoring systems in earlier studies when studied in similar at-home conditions. The overall patient satisfaction was high.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Nyckelord

Diabetes mellitus
Flash glucose monitor
Accuracy
randomized controlled-trial
glycemic control
system
Endocrinology & Metabolism
Diabetes mellitus; Flash glucose monitor; Accuracy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy