SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/255853"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/255853" > TiO2 nanomaterial d...

TiO2 nanomaterial detection in calcium rich matrices by spICPMS. A matter of resolution and treatment

Tharaud, M. (författare)
Gondikas, Andreas P., 1981 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för marina vetenskaper,Department of marine sciences
Benedetti, M. F. (författare)
visa fler...
von der Kammer, F. (författare)
Hofmann, T. (författare)
Cornelis, G. (författare)
visa färre...
 (creator_code:org_t)
2017
2017
Engelska.
Ingår i: Journal of Analytical Atomic Spectrometry. - : Royal Society of Chemistry (RSC). - 0267-9477 .- 1364-5544. ; 32:7, s. 1400-1411
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • High Ca concentrations in complex matrices such as river waters often hamper the detection of titanium nanomaterials (TiO2 NPs) by single particle inductively coupled plasma mass spectrometry (spICPMS), because of isobaric interference of Ca-48 on the most abundant Ti isotope (Ti-48). Several approaches were used to reduce this interference while measuring TiO2 in solutions with different Ca concentrations up to 100 mg L-1. ICP-MS/MS was used with ammonia as the reaction ceLL gas and high resoLution (HR) ICP-MS was used under different resoLution settings. These approaches were compared by measuring different Ti isotopes (Ti-47 and Ti-49). spICPMS data were then treated with a deconvoLution method to filter out dissolved signals and identify the best approach to detect the Lowest possible corresponding spherical size of TiO2 NPs (D,in). ICP-MS/MS aLLowed for an important decrease of the theoretical D-min compared to standard quadrupole ICP-MS, down to 64 nm in uLtrapure water; however the sensitivity was reduced by the reaction gas and increasing Ca concentrations also increased the D-min. The comparably higher sensitivity of HR-ICP-MS aLLowed for theoretically measuring a D-min of 10 nm in uLtrapure water. Combined with the deconvoLution analysis, the highest resoLution mode in HR-ICP-MS Leads to the Lowest D-min at high Ca concentrations, even though significant broadening of the measured mass distributions occurred for TiO2 NPs at Ca concentrations up to 100 mg L-1.

Ämnesord

NATURVETENSKAP  -- Geovetenskap och miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences (hsv//eng)

Nyckelord

inductively-coupled plasma
particle icp-ms
mass-spectrometry
silver
nanoparticles
titanium-dioxide
sunscreens
chemistry
waters
signal
Chemistry
Spectroscopy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy