SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/260099"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/260099" > Generating ActiGrap...

Generating ActiGraph Counts from Raw Acceleration Recorded by an Alternative Monitor

Brond, J. C. (författare)
Andersen, L. B. (författare)
Arvidsson, Daniel, 1974 (författare)
Gothenburg University,Göteborgs universitet,Centrum för hälsa och prestationsutveckling,Institutionen för kost- och idrottsvetenskap,Center for Health and Performance,Department of Food and Nutrition, and Sport Science
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2017
2017
Engelska.
Ingår i: Medicine and Science in Sports and Exercise. - : Ovid Technologies (Wolters Kluwer Health). - 0195-9131. ; 49:11, s. 2351-2360
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: This study aimed to implement an aggregation method in Matlab for generating ActiGraph counts from raw acceleration recorded with an alternative accelerometer device and to investigate the validity of the method. Methods: The aggregation method, including the frequency band-pass filter, was implemented and optimized based on standardized sinusoidal acceleration signals generated in Matlab and processed in the ActiLife software. Evaluating the validity of the aggregation method was approached using a mechanical setup and with a 24-h free-living recording using a convenient sample of nine subjects. Counts generated with the aggregation method applied to Axivity AX3 raw acceleration data were compared with counts generated with ActiLife from ActiGraph GT3X+ data. Results: An optimal band-pass filter was fitted resulting in a root-mean-square error of 25.7 counts per 10 s and mean absolute error of 15.0 counts per second across the full frequency range. The mechanical evaluation of the proposed aggregation method resulted in an absolute mean +/- SD difference of -0.11 +/- 0.97 counts per 10 s across all rotational frequencies compared with the original ActiGraph method. Applying the aggregation method to the 24-h free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 s, a relative difference in the averaged physical activity (counts per minute) ranging from -0.5% to 4.7% with a group mean +/- SD of 2.2% +/- 1.7%, and a Cohen' s kappa of 0.945, indicating almost a perfect agreement in the intensity classification. Conclusion: The proposed band-pass filter and aggregation method is highly valid for generating ActiGraph counts from raw acceleration data recorded with alternative devices. It would facilitate comparability between studies using different devices collecting raw acceleration data.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Nyckelord

gt3x
physical activity
filtering
algorithms
validation
physical-activity
observer agreement
accelerometer data
Sport Sciences

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Brond, J. C.
Andersen, L. B.
Arvidsson, Danie ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
Artiklar i publikationen
Medicine and Sci ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy