SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/260415"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/260415" > Evaluation of polyu...

Evaluation of polyurethane foam passive air sampler (PUF) as a tool for occupational PAH measurements

Strandberg, Bo, 1960 (författare)
University of Gothenburg,Lund University,Lunds universitet,Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa,Institute of Medicine, School of Public Health and Community Medicine,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Julander, A. (författare)
Karolinska Institutet,Karolinska Institute
Sjöström, M. (författare)
Karolinska Institutet,Stockholm County Council,Karolinska Institute
visa fler...
Lewné, M. (författare)
Karolinska Institutet,Stockholm County Council,Karolinska Institute
Koca Akdeva, Hatice (författare)
University of Gothenburg,Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa,Institute of Medicine, School of Public Health and Community Medicine
Bigert, C. (författare)
Karolinska Institutet,Stockholm County Council,Karolinska Institute
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Chemosphere. - : Elsevier BV. - 0045-6535 .- 1879-1298. ; 190, s. 35-42
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Routine monitoring of workplace exposure to polycyclic aromatic hydrocarbons (PAHs) is performed mainly via active sampling. However, active samplers have several drawbacks and, in some cases, may even be unusable. Polyurethane foam (PUF) as personal passive air samplers constitute good alternatives for PAH monitoring in occupational air (8 h). However, PUFs must be further tested to reliably yield detectable levels of PAHs in short exposure times (1–3 h) and under extreme occupational conditions. Therefore, we compared the personal exposure monitoring performance of a passive PUF sampler with that of an active air sampler and determined the corresponding uptake rates (Rs). These rates were then used to estimate the occupational exposure of firefighters and police forensic specialists to 32 PAHs. The work environments studied were heavily contaminated by PAHs with (for example) benzo(a)pyrene ranging from 0.2 to 56 ng m−3, as measured via active sampling. We show that, even after short exposure times, PUF can reliably accumulate both gaseous and particle-bound PAHs. The Rs-values are almost independent of variables such as the concentration and the wind speed. Therefore, by using the Rs-values (2.0–20 m3 day−1), the air concentrations can be estimated within a factor of two for gaseous PAHs and a factor of 10 for particulate PAHs. With very short sampling times (1 h), our method can serve as a (i) simple and user-friendly semi-quantitative screening tool for estimating and tracking point sources of PAH in micro-environments and (ii) complement to the traditional active pumping methods. © 2017 The Authors

Ämnesord

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Folkhälsovetenskap, global hälsa, socialmedicin och epidemiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Public Health, Global Health, Social Medicine and Epidemiology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

Exposure
Firefighter
Occupational exposure
PAH
Passive sampler
PUF
Aromatic hydrocarbons
Fire extinguishers
Fire fighting equipment
Petroleum industry
Polyurethanes
Rigid foamed plastics
Wind
Passive air sampler
Passive samplers
Personal exposure monitoring
Polycyclic aromatic hydrocarbons (PAHS)
Quantitative screening
Polycyclic aromatic hydrocarbons
polycyclic aromatic hydrocarbon
polyurethan foam
air quality
atmospheric pollution
concentration (composition)
foam
monitoring
monitoring system
pollution exposure
pollution incidence
sampler
sampling
tracking
workplace
air monitoring
air pollution
air sampler
air sampling
Article
controlled study
fire fighter
human
measurement
particulate matter
police
screening

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy