SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/270476"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/270476" > Retrospective estim...

Retrospective estimation of heart and lung doses in pediatric patients treated with spinal irradiation

Gasic, D. (författare)
af Rosenschold, P. M. (författare)
Vogelius, I. R. (författare)
visa fler...
Maraldo, M. V. (författare)
Aznar, M. C. (författare)
Nysom, K. (författare)
Björk-Eriksson, Thomas, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences, Department of Oncology
Bentzen, S. M. (författare)
Brodin, N. P. (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140. ; 128:2, s. 209-213
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose: The purpose of this study was to investigate whether treatment information from medical records can be used to estimate radiation doses to heart and lungs retrospectively in pediatric patients receiving spinal irradiation with conventional posterior fields. Material and methods: An algorithm for retrospective dosimetry in children treated with spinal irradiation was developed in a cohort of 21 pediatric patients with available CT-scans and treatment plans. We developed a multivariable linear regression model with explanatory variables identifiable in case note review for retrospective estimation of minimum, maximum, mean and V-10%-V-80% doses to the heart and lungs. Doses were estimated for both linear accelerator (Linac) and Co-60 radiation therapy modalities. Results: Age and spinal field width were identified as statistically significant predictors of heart and lung doses in multivariable analyses (p < 0.01 in all models). Models showed excellent predictive performance with R-2 = 0.70 for mean heart dose and 0.79 for mean lung dose, for Linac plans. In leave-one-out cross-validation analysis the average difference between predicted and actual mean heart dose was 6.7% and 7.6% of the prescription dose for Linac and Co-60 plans, respectively, and 5.2% and 4.9% for mean lung dose. Due to the small sample size and large inter-patient variation in heart and lung dose, prospective studies validating these findings are highly warranted. Conclusions: The models presented here provide retrospective estimates of heart and lung doses for historical cohorts of pediatric patients, thus facilitating studies of long-term adverse effects of radiation. (C) 2018 Elsevier B.V. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

Pediatric spinal irradiation
Retrospective dosimetry
Heart and lungs
Linear regression models
Dose
disease following treatment
childhood-cancer survivor
breast-cancer
radiation-therapy
hodgkins-disease
radiotherapy
chemotherapy
reconstruction
lymphoma
women

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy