SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/271371"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/271371" > Variable Flip Angle...

Variable Flip Angle 3D Ultrashort Echo Time (UTE) T-1 Mapping of Mouse Lung: A Repeatability Assessment

Alamidi, Daniel (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Philips Health Systems,University of Gothenburg
Smailagic, A. (författare)
AstraZeneca AB,AstraZeneca, UK
Bidar, A. W. (författare)
AstraZeneca AB,AstraZeneca, UK
visa fler...
Parker, N. S. (författare)
AstraZeneca AB,AstraZeneca, UK
Olsson, M. (författare)
AstraZeneca AB,AstraZeneca, UK
Hockings, Paul, 1956 (författare)
Chalmers University of Technology
Lagerstrand, Kerstin M (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
Olsson, Lars E. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2018-03-08
2018
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 48:3, s. 846-852
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Lung T-1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T-1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. Purpose: To evaluate the feasibility of regional lung T-1 quantification with VFA 3D-UTE and to investigate long-and short-term T-1 repeatability in the lungs of naive mice. Field strength/Sequence: 3D free-breathing radial UTE (8 mu s) at 4.7T. Assessment: VFA 3D-UTE T-1 calculations were validated against T-1 values measured with inversion recovery (IR) in phantoms. Lung T-1 and proton density (S-0) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T-1 measurements were performed during one of the imaging sessions. Statistical Tests: Agreement in T-1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson's correlation analysis. The T-1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Results: Good T-1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T-1 in lung and muscle showed a 5% and 3% CV (1255 +/- 63 msec and 1432 +/- 42 msec, respectively, mean +/- SD) with no changes in T-1 or S-0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T-1 and S-0. Data Conclusion: VFA 3D-UTE shows promise as a reliable T-1 mapping method that enables full lung coverage, high signal-to-noise ratio (similar to 25), and spatial resolution (300 mu m) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

neurogenic pulmonary-edema
relaxation-time
animal-model
mri
isoflurane
disease
copd
rats
t1
Radiology
Nuclear Medicine & Medical Imaging
ristoffersson jo
1991
acta radiologica
v32
p426
biomarker
3D radial
Biomarker
Longitudinal relaxation time
Lung imaging
Mouse
T mapping

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy