Interleukin-6 measured using the automated electrochemiluminescence immunoassay method for the identification of intra-amniotic inflammation in preterm prelabor rupture of membranes.
-
Musilova, Ivana (author)
-
Andrys, Ctirad (author)
-
Holeckova, Magdalena (author)
-
show more...
-
Kolarova, Veronika (author)
-
Pliskova, Lenka (author)
-
Drahosova, Marcela (author)
-
Bolehovska, Radka (author)
-
Pilka, Radovan (author)
-
Huml, Karel (author)
-
Cobo, Teresa (author)
-
- Jacobsson, Bo, 1960 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
-
Kacerovsky, Marian (author)
-
show less...
-
(creator_code:org_t)
- 2018-12-17
- 2020
- English.
-
In: The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. - : Informa UK Limited. - 1476-4954. ; 33:11, s. 1919-1926
- Related links:
-
https://gup.ub.gu.se...
-
show more...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- We aimed to compare the amniotic fluid interleukin (IL)-6 concentrations measured using the automated electrochemiluminescence immunoassay method and ELISA, and to establish an IL-6 concentration cut-off value for intra-amniotic inflammation (IAI) in preterm prelabor rupture of membranes (PPROM), which can be used in the automated electrochemiluminescence immunoassay method.A total of 120 women with PPROM were included in this study. Amniotic fluid samples were obtained via transabdominal amniocentesis. IL-6 concentrations were assessed using both the automated electrochemiluminescence immunoassay method and ELISA, the current gold standard. IAI was defined as an amniotic fluid IL-6 concentration of ≥ 2600 pg/mL measured using ELISA.A correlation between both assays was found (Spearman's rho = 0.97; p < 0.0001). Based on the receiver-operating characteristic curve for the identification of IAI (area under the curve = 0.99), a cut-off value of ≥ 3000pg/mL was selected for the automated electrochemiluminescence immunoassay method with a sensitivity of 88%, specificity of 99%, positive predictive value of 97%, negative predictive value of 96%, and likelihood ratio of 76.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Musilova, Ivana
-
Andrys, Ctirad
-
Holeckova, Magda ...
-
Kolarova, Veroni ...
-
Pliskova, Lenka
-
Drahosova, Marce ...
-
show more...
-
Bolehovska, Radk ...
-
Pilka, Radovan
-
Huml, Karel
-
Cobo, Teresa
-
Jacobsson, Bo, 1 ...
-
Kacerovsky, Mari ...
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Obstetrics Gynae ...
- Articles in the publication
-
The journal of m ...
-
The Journal of M ...
- By the university
-
University of Gothenburg