SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/279057"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/279057" > Clinical evaluation...

Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.

Odenstedt Hergès, Helena (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Stenqvist, O (författare)
Lundin, S (författare)
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Acta anaesthesiologica Scandinavica. - 0001-5172. ; 46:2, s. 152-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Monitoring central hemodynamics is essential in critically ill patients and less invasive techniques are needed. In this study, the clinical and technical performance of a new non-invasive cardiac output monitor (NICO) based on partial CO2 rebreathing technique and a modified Fick equation were evaluated. The various sources of possible errors in measurement of cardiac output (CO), carbon dioxide production (VCO2) and pulmonary shunt were also assessed.Simultaneous measurements of CO with partial CO2 rebreathing technique (CO(nico)) and thermodilution (CO(td)) were performed in 15 patients during major surgery or in the ICU. Pulmonary shunt was estimated from this device and compared to values obtained by standard shunt formula. The accuracy of VCO2 measurements was assessed in a mechanical lung model.A good correlation was found between CO(nico) and CO(td) (r = 0.96, within-subject correlation r = 0.88) with a small underestimation of cardiac output by the NICO of 0.04 L/min, limits of agreement (+/- 2 SD) being - 1.68 and 1.76 L/min. In hemodynamic unstable patients the method closely tracked changes in CO. Pulmonary shunt was underestimated by approximately 11%-units compared to standard shunt calculations using arterial and mixed venous blood gases. We also observed an underestimation in VCO2 measurements.Clinical evaluation shows that partial CO2 rebreathing technique provides a useful and accurate non-invasive estimate of cardiac output. Although this technique cannot fully replace the pulmonary artery catheter, it may be used to monitor central hemodynamics in a large number of critically ill patients.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Nyckelord

Adult
Aged
Aged
80 and over
Carbon Dioxide
metabolism
Cardiac Output
Critical Illness
Female
Humans
Male
Middle Aged
Monitoring
Physiologic
methods
Respiration

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Odenstedt Hergès ...
Stenqvist, O
Lundin, S
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Anestesi och int ...
Artiklar i publikationen
Acta anaesthesio ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy