SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/285659"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/285659" > A morphometric and ...

A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone.

Sennerby, Lars, 1960 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Thomsen, Peter, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
Ericson, Lars, 1943 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för anatomi och cellbiologi,Institute of Anatomy and Cell Biology
 (creator_code:org_t)
1992
1992
Engelska.
Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 7:1, s. 62-71
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The removal torques for screw-shaped pure titanium implants inserted in rabbit tibia and the femoral part of the knee joint and the tissue response to these implants, as quantitated with light microscopic morphometry on ground sections, were compared after 6 weeks, 3 months, and 6 months. The bone surrounding the femoral intra-articular implants was mostly cancellous, while cortical bone was formed around the tibial implants. The torque needed to remove the intra-articular implants increased with time, but there was no such increase for the tibial implants. At 6 weeks, significantly less torque was needed to remove the intra-articular implants in spite of the fact that significantly more bone was found in the threads of these implants as compared with the tibial implants. When calculating the amount of bone in threads situated in the cortical and subchondral passage, more was found in the threads of the tibial implants, which corresponded to the higher removal torque. Additional light microscopic observations on implants unscrewed after 12 months in rabbit tibia indicated that rupture occurred between the implant surface and calcified bone. Findings indicate that the resistance to unscrewing is dependent on the amount of compact bone surrounding a titanium implant.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Animals
Bone Density
Bone and Bones
anatomy & histology
physiology
Knee Joint
physiology
Osseointegration
Prostheses and Implants
Rabbits
Rotation
Stress
Mechanical
Titanium

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sennerby, Lars, ...
Thomsen, Peter, ...
Ericson, Lars, 1 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinsk biotek ...
och Biomaterialveten ...
Artiklar i publikationen
The Internationa ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy